GT
Gas Trouble
Zone disabled by fault
Zone or point
GU
Gas Unbypass
Bypass has been removed
Zone or point
GX
Gas Test
Zone activated during test
Zone or point
HA
Holdup Alarm
Silent alarm, user under duress
Zone or point
HB
Holdup Bypass
Zone has been bypassed
Zone or point
HH
Holdup Alarm
Restore
Alarm condition eliminated
Zone or point
HJ
Holdup Trouble
Restore
Trouble condition eliminated
Zone or point
HR
Holdup Restoral
Alarm/trouble condition has been eliminated
Zone or point
HS
Holdup Supervisory
Unsafe holdup system condition
Zone or point
HT
Holdup Trouble
Zone disabled by fault
Zone or point
HU
Holdup Unbypass
Bypass has been removed
Zone or point
IA
Equipment Failure
Condition
A specific, reportable condition is detected on a device
Point number
IR
Equipment Fail -
Restoral
The equipment condition has been restored to normal
Point number
JA
User Code Tamper
Too many unsuccessful attempts have been made to enter a user
ID
Area number
JD
Date Changed
The date was changed in the transmitter/receiver
User number
JH
Holiday Changed
The transmitter's holiday schedule has been changed
User number
JK
Latchkey Alert
A designated user passcode has not been entered during a
scheduled time window
User number
JL
Log Threshold
The transmitter's log memory has reached its threshold level
Unused
JO
Log Overflow
The transmitter's log memory has overflowed
Unused
JP
User On Premises
A designated user passcode has been used to gain access to the
premises.
User number
JR
Schedule Executed
An automatic scheduled event was executed
Area number
JS
Schedule Changed
An automatic schedule was changed
User number
JT
Time Changed
The time was changed in the transmitter/receiver
User number
JV
User Code Changed
A user's code has been changed
User number
JX
User Code Deleted
A user's code has been removed
User number
JY
User Code Added
A user’s code has been added
User number
JZ
User Level Set
A user’s authority level has been set
User number
KA
Heat Alarm
High temperature detected on premise
Zone or point
KB
Heat Bypass
Zone has been bypassed
Zone or point
KH
Heat Alarm Restore
Alarm condition eliminated
Zone or point
KJ
Heat Trouble
Restore
Trouble condition eliminated
Zone or point
KR
Heat Restoral
Alarm/trouble condition has been eliminated
Zone or point
KS
Heat Supervisory
Unsafe heat detection system condition
Zone or point
KT
Heat Trouble
Zone disabled by fault
Zone or point
KU
Heat Unbypass
Bypass has been removed
Zone or point
LB
Local Program
Begin local programming
Unused
LD
Local Program
Denied
Access code incorrect
Unused
LE
Listen-in Ended
The listen-in session has been terminated
Unused
LF
Listen-in Begin
The listen-in session with the RECEIVER has begun
Unused
LR
Phone Line Restoral
Phone line restored to service
Line number
LS
Local Program
Success
Local programming successful
Unused
LT
Phone Line Trouble
Phone line trouble report
Line number
LU
Local Program Fail
Local programming unsuccessful
Unused
LX
Local Programming
Ended
A local programming session has been terminated
Unused
MA
Medical Alarm
Emergency assistance request
Zone or point
MB
Medical Bypass
Zone has been bypassed
Zone or point
MH
Medical Alarm
Restore
Alarm condition eliminated
Zone or point
MI
Message
A canned message is being sent
Message number
MJ
Medical Trouble
Restore
Trouble condition eliminated
Zone or point
MR
Medical Restoral
Alarm/trouble condition has been eliminated
Zone or point
MS
Medical Supervisory
Unsafe system condition exists
Zone or point
MT
Medical Trouble
Zone disabled by fault
Zone or point
MU
Medical Unbypass
Bypass has been removed
Zone or point
NA
No Activity
There has been no zone activity for a programmed amount of
time
Zone number
NC
Network Condition
A communications network has a specific reportable condition
Network number
NF
Forced Perimeter
Arm
Some zones/points not ready
Area number
NL
Perimeter Armed
An area has been perimeter armed
Area number
NM
Perimeter Armed,
User Defined
A user defined area has been perimeter armed
Area number
NR
Network Restoral
A communications network has returned to normal operation
Network number
NS
Activity Resumed
A zone has detected activity after an alert
Zone number
NT
Network Failure
A communications network has failed
Network number
OA
Automatic Opening
System has disarmed automatically
Area number
OC
Cancel Report
Untyped zone cancel
User number
OG
Open Area
System has been partially disarmed
Area number
Data Code Short Description
Long Description
Address Field