background image

28

                                                                                                                                Sentinel & PimaGuard

  Installation Guide

A

PPENDIX

 C      F

AULT

 C

ODES

All PimaGuard fault codes are sent in 4x2 format with the error account number or, if set, the repeater's supervision 
account number.

* The Radio and Line channels are distinguished by the protocol. Internal errors are sent with line distinguishers.

If a repeater test/fail account is set, the repeater faults are sent with TN; else, they are sent with the Central Monitoring Station's 
faults account

Code Failure

Code Restore

01

*Phone\Radio Fail 1

81

*Phone\Radio Restore 1

02

*Phone\Radio Fail 2

82

*Phone\Radio Restore 2

03

*Phone\Radio Fail 3

83

*Phone\Radio Restore 3

04

*Phone\Radio Fail 4

84

*Phone\Radio Restore 4

05

*Phone\Radio Fail 5

85

*Phone\Radio Restore 5

06

*Phone\Radio Fail 6

86

*Phone\Radio Restore 6

07

*Phone\Radio Fail 7

87

*Phone\Radio Restore 7

08

*Phone\Radio Fail 8

88

*Phone\Radio Restore 8

09

*Phone\Radio Fail 9

89

*Phone\Radio Restore 9

0A

*Phone\Radio Fail 10

8A

*Phone\Radio Restore 10

0B

*Phone\Radio Fail 11

8B

*Phone\Radio Restore 11

0C

*Phone\Radio Fail 12

8C

*Phone\Radio Restore 12

0D

*Phone\Radio Fail 13

8D

*Phone\Radio Restore 13

0E

*Phone\Radio Fail 14

8E

*Phone\Radio Restore 14

0F

*Phone\Radio Fail 15

8F

*Phone\Radio Restore 15

10

*Phone\Radio Fail 16

90

*Phone\Radio Restore 16

11

Phone Fail 17

91

Phone Restore 17

12

Phone Fail 18

92

Phone Restore 18

13

Phone Fail 19

93

Phone Restore 19

14

Phone Fail 20

94

Phone Restore 20

15

Phone Fail 21

95

Phone Restore 21

16

Phone Fail 22

96

Phone Restore 22

17

Phone Fail 23

97

Phone Restore 23

18

Phone Fail 24

98

Phone Restore 24

19

Phone Fail 25

99

Phone Restore 25

1A

Phone Fail 26

9A

Phone Restore 26

1B

Phone Fail 27

9B

Phone Restore 27

1C

Phone Fail 28

9C

Phone Restore 28

1D

Phone Fail 29

9D

Phone Restore 29

1E

Phone Fail 30

9E

Phone Restore 30

1F

Phone Fail 31

9F

Phone Restore 31

20

Phone Fail 32

A0

Phone Restore 32

21

Comm 1 Fail

A1

Comm 1 Restore

22

Comm 2 Fail

A2

Comm 2 Restore

23

Comm 3 Fail

A3

Comm 3 Restore

24

Comm 4 Fail

A4

Comm 4 Restore

25

Comm 5 Fail

A5

Comm 5 Restore

26

Comm 6 Fail

A6

Comm 6 Restore

27

Comm 7 Fail

A7

Comm 7 Restore

28

Comm 8 Fail

A8

Comm 8 Restore

29

Log 1 Fail

A9

Log 1 Restore

2A

Log 2 Fail

AA

Log 2 Restore

2B

Log 3 Fail

AB

Log 3 Restore

2C

Log 4 Fail

AC

Log 4 Restore

Code Failure

Code Restore

2D

Repeater 1  Channel 1 Fail

AD

Repeater 1  Channel 1 Restore

2E

Repeater 1  Channel 2 Fail

AE

Repeater 1  Channel 2 Restore

2F

Repeater 1  Channel 3 Fail

AF

Repeater 1  Channel 3 Restore

30

Repeater 1  Channel 4 Fail

B0

Repeater 1  Channel 4 Restore

31

Repeater 2 Channel 1 Fail

B1

Repeater 2 Channel 1 Restore

32

Repeater 2 Channel 2 Fail

B2

Repeater 2 Channel 2 Restore

33

Repeater 2 Channel 3 Fail

B3

Repeater 2 Channel 3 Restore

34

Repeater 2 Channel 4 Fail

B4

Repeater 2 Channel 4 Restore

35

Repeater 3 Channel 1 Fail

B5

Repeater 3 Channel 1 Restore

36

Repeater 3 Channel 2 Fail

B6

Repeater 3 Channel 2 Restore

37

Repeater 3 Channel 3 Fail

B7

Repeater 3 Channel 3 Restore

38

Repeater 3 Channel 4 Fail

B8

Repeater 3 Channel 4 Restore

39

Repeater 4 Channel 1 Fail

B9

Repeater 4 Channel 1 Restore

3A

Repeater 4 Channel 2 Fail

BA

Repeater 4 Channel 2 Restore

3B

Repeater 4 Channel 3 Fail

BB

Repeater 4 Channel 3 Restore

3C

Repeater 4 Channel 4 Fail

BC

Repeater 4 Channel 4 Restore

3D

Repeater 5 Channel 1 Fail

BD

Repeater 5 Channel 1 Restore

3E

Repeater 5 Channel 2 Fail

BE

Repeater 5 Channel 2 Restore

3F

Repeater 5 Channel 3 Fail

BF

Repeater 5 Channel 3 Restore

40

Repeater 5 Channel 4 Fail

C0

Repeater 5 Channel 4 Restore

41

Repeater 6 Channel 1 Fail

C1

Repeater 6 Channel 1 Restore

42

Repeater 6 Channel 2 Fail

C2

Repeater 6 Channel 2 Restore

43

Repeater 6 Channel 3 Fail

C3

Repeater 6 Channel 3 Restore

44

Repeater 6 Channel 4 Fail

C4

Repeater 6 Channel 4 Restore

45

Repeater 7 Channel 1 Fail

C5

Repeater 7 Channel 1 Restore

46

Repeater 7 Channel 2 Fail

C6

Repeater 7 Channel 2 Restore

47

Repeater 7 Channel 3 Fail

C7

Repeater 7 Channel 3 Restore

48

Repeater 7 Channel 4 Fail

C8

Repeater 7 Channel 4 Restore

49

Repeater 8 Channel 1 Fail

C9

Repeater 8 Channel 1 Restore

4A

Repeater 8 Channel 2 Fail

CA

Repeater 8 Channel 2 Restore

4B

Repeater 8 Channel 3 Fail

CB

Repeater 8 Channel 3 Restore

4C

Repeater 8 Channel 4 Fail

CC

Repeater 8 Channel 4 Restore

Summary of Contents for PIMAGUARD

Page 1: ...SENTINEL Receiver Decoder PCI Card PIMAGUARD Configuration Application Installation and Operating Guide PIMA Electronic Systems Ltd www pima alarms com P N 4410051 F1 XX en Feb 2011...

Page 2: ...2 Sentinel PimaGuard Installation Guide...

Page 3: ...unication formats 14 Creating a new format 14 Programming 16 Sentinel 1 16 Sentinel configuration 16 Line 1 configuration 16 Radio 1 18 Communication 18 Type 19 Mode 19 On error switch to 19 Examples...

Page 4: ...29 Legend 29 Source options examples 30 Structured Formats 30 Appendix E Events Conversion Table 36 NPAF EPAF 40 ELL6 49 CID PID 50 SIA 55 Appendix F Programming Line Radio Formats 60 Line Formats 60...

Page 5: ...for each channel PAF CID SIA KP DESK ELL and more Automatic testing of the card and the input channel Failures and status are reported to the Central Monitoring Station management application Up to 4...

Page 6: ...inel package contains the following The Sentinel Card The PimaGuard driver installation CD A radio connection cable P N 3411055 4 RJ 11 standard telephone cords P N 3411046 Cross link 9 pin D type ser...

Page 7: ...ntinel insert the others too max 4 cards 4 Close the PC case plug it and turn it on Installing several Sentinels When you install several Sentinels up to 4 the procedure is as folllows 1 Insert the ca...

Page 8: ...reception signal is not interrupted by the squelch filter PIMAGUARD INSTALLATION Under Windows XP After installing the Sentinel when Windows boots up the Add New Hardware Wizard should start running a...

Page 9: ...stall from a list or specific location and click Next 4 Select Don t search I will choose the driver to install and click Next 5 Press Have Disk If the PimaGuard was previously intalled on the PC disr...

Page 10: ...e desktop right click the My Computer icon and select Manage In the window that pops up click Device Manager on the left pane 2 Right click the first Network Controller and select Update Driver Softwa...

Page 11: ...k Install this driver software anyway 10 Wait for the installation to end with the message Windows has successfully updated your driver software and click Close When Working under Windows 7 the UAC Us...

Page 12: ...t levels of the menu and for all parameters and text fields Copy Paste Clear Formats filters ACKs and other parameters can be copied by using the Copy command on the main menu Pasting the copied infor...

Page 13: ...count 8000 in most cases This PimaGuard self account fault event is sent to the Central Monitoring Station via all the modules each in its own protocol If you don t set any event the PimaGuard will no...

Page 14: ...30 Burglary can be converted to Hex 2 digits and be sent as 82 The full event conversion table is in Appendix E page 36 A legend of the characters of the Formats page is located on page 29 Creating a...

Page 15: ...s example CID PID events will be converted to Hex 2 Digit format see the conversion table on page 40 If for example event 130 Burglary is received it will be converted to 82 The first E in the Contact...

Page 16: ...nterval and only if the 3 fail a report will be generated See Appendix C page 28 6 Click OK The pop up window is shut down and the Line settings are displayed in the PimaGuard window 7 On the right pa...

Page 17: ...ter P will be displayed with its value Else the structured format will be displayed as followed S System F Flag E Extra Other information will follow Filters Add to Account Structure PLS and DTMF only...

Page 18: ...in milliseconds to enable the full charging of the transmitter after pushing PTT before transmitting a report Empty 180 ms min 80 max 640 5 Press OK Radio format The Radio format window is the same a...

Page 19: ...DOS Compatible mode it supports all format types See the repeaters on page page 25 On error switch to Select the communication channel to which the output transmissions will be switched when an error...

Page 20: ...nt is not within the filter s range except for time filters This is to enable the external decoder to keep running in anyway Idle timeout 7 Set the Idle timeout in seconds To view ACK Idle patterns se...

Page 21: ...ral debug To switch between the two double click the Mode line in the right pane The Debug mode can be operated only with a Sentinel card installed Figure 17 The monitor window General In this mode th...

Page 22: ...s Yellow Warning some features will not work properly Potential loss of data Red Error some features will not work at all or not work properly Potential loss of data Oscillograph This mode enables you...

Page 23: ...is displayed in this window 5 Press browse and locate the upgrade file Press Open 6 Press Program than Start If the upgrade version is the same as the PimaGuard s one a warning message will be display...

Page 24: ...ht pane 9 Select the incoming transmission s format from the drop down list From the list PAF NPAF EPAF DESK are Radio and PSTN formats PID SIA CID are supported if a non dos compatible PID repeater t...

Page 25: ...be received by the PimaGuard and what will not The filters are Account Event Date Days Time Format and Channel The Filters window appears the same in every channel and module but is set separately fo...

Page 26: ...tells the PimaGuard to receive transmissions only from Comm 2 After that the PimaGuard reads the content of the file under the list limit no and compares it to the transmission s content only matching...

Page 27: ...ainst wetness 4 The antenna cable should not run in parallel to any electric wires to avoid RF interferences If this is unavoidable the cable should run at least 1 meter away from the electric wires 5...

Page 28: ...e 26 Comm 6 Fail A6 Comm 6 Restore 27 Comm 7 Fail A7 Comm 7 Restore 28 Comm 8 Fail A8 Comm 8 Restore 29 Log 1 Fail A9 Log 1 Restore 2A Log 2 Fail AA Log 2 Restore 2B Log 3 Fail AB Log 3 Restore 2C Log...

Page 29: ...peater Channel Line Radio COMM Decoder ID is taken from the user definitions of the input format decimal 0 default Source options every 2 characters represent a condition and its value to be placed in...

Page 30: ...ut from Radio A 4 digit account decimal E 2 digit event Atia 13 Expanded Frame Structure R1L3 AAAA EE 0A 0D 3 Input from Line or other 1 Input from Radio A 4 digit account decimal E 2 digit event In C...

Page 31: ...the output is External the 4x2 protocol is the default one If required use FBI External FBI PAF CID Frame Structure AAAAEE 0D applicable to SIA 4x2 Frame Structure 0A AAAA 18 QEEE PP ZZZ 0D Applicabl...

Page 32: ...Configuration See Configuration on page 13 FBI DESK Frame Structure AAAAEE 0D Applicable to PAF NPAF EPAF SIA 4x2 Incoming Sentinel Communication Repeater channel number A 4 digit account decimal E 2...

Page 33: ...SURGARD PAF HEX Frame Structure 10 AAAA EE 14 Applicable to PAF NPAF EPAF 4x2 Frame Structure 50 18AAAAQEEE ZZZ 14 Applicable to CID PID Frame Structure 30 AAAAEE ZZZ 14 Applicable to SIA The structu...

Page 34: ...ecimal E 2 digit event CC CRC Frame Structure 0A SSSSSSSSSSSSSSSSSSS AAAAAAEEK______CC 0D Applicable to NPAF EPAF PAF SSSSSSSSSSSSSSSSSSS A 6 digit account decimal E 2 digit event K Multiple Condition...

Page 35: ...count decimal Note that it is 0A AAAA and not 5 digit account number E 2 digit event Hexadecimal 4x2 only COMPUCHER Frame Structure 0A SSSSSSSSSSSSSSSSSSS AAAAAAEE_______CC 0D Applicable to 4x2 SSSSSS...

Page 36: ...event E 3 digit event P 2 digit Partition decimal S Ademco 685 Special U User Event C Contact Event Z 3 digit Zone User decimal APPENDIX E EVENTS CONVERSION TABLE This appendix lists build in formats...

Page 37: ...1 7 A 16 Alarm zone 42 LD 20 130 1 42 7 A 16 Alarm zone 43 LE 20 130 1 43 B A 16 Alarm zone 44 LF 20 130 1 44 F A 16 Alarm zone 45 LG 20 130 1 45 A A 16 Alarm zone 46 LH 20 130 1 46 8 A 16 Alarm zone...

Page 38: ...14 8 O Disarming User 15 NY BD 401 1 15 8 O Disarming User 16 NZ BD 401 1 16 8 O Disarming User 17 OA BD 401 1 17 8 O Disarming User 18 OB BD 401 1 18 8 O Disarming User 19 OC BD 401 1 19 8 O Disarmi...

Page 39: ...1 3 11 A C Home User 12 QX A5 401 3 12 A C Arming Auto QY EF 403 3 0 A C Disarming Auto QZ F0 403 1 0 A C Home Auto RA EF 403 3 0 A C Arming Switch RB 97 409 3 0 A C Disarming Switch RC C1 409 1 0 A C...

Page 40: ...30 1 1 B A 1 Alarm Zone 2 AB 01 130 1 2 4 A 2 Alarm Zone 3 AC 02 130 1 3 9 A 3 Alarm Zone 4 AD 03 130 1 4 9 A 4 Alarm Zone 5 AE 04 130 1 5 E A 5 Alarm Zone 6 AF 05 130 1 6 6 A 6 Alarm Zone 7 AG 06 130...

Page 41: ...80 DB 20 130 1 80 0 A 16 Alarm Zone 81 DC 20 130 1 81 0 A 16 Alarm Zone 82 DD 20 130 1 82 0 A 16 Alarm Zone 83 DE 20 130 1 83 0 A 16 Alarm Zone 84 DF 20 130 1 84 0 A 16 Alarm Zone 85 DG 20 130 1 85 0...

Page 42: ...0 R 16 Zone Reset 71 GK 41 130 3 71 0 R 16 Zone Reset 72 GL 41 130 3 72 0 R 16 Zone Reset 73 GM 41 130 3 73 0 R 16 Zone Reset 74 GN 41 130 3 74 0 R 16 Zone Reset 75 GO 41 130 3 75 0 R 16 Zone Reset 76...

Page 43: ...JR 62 380 1 60 0 T 16 Zone Failure 61 JS 62 380 1 61 0 T 16 Zone Failure 62 JT 62 380 1 62 0 T 16 Zone Failure 63 JU 62 380 1 63 0 T 16 Zone Failure 64 JV 62 380 1 64 0 T 16 Zone Failure 65 JW 62 380...

Page 44: ...50 0 X 25 Zone Bypass 51 NA 83 570 1 51 0 X 25 Zone Bypass 52 NB 83 570 1 52 0 X 25 Zone Bypass 53 NC 83 570 1 53 0 X 25 Zone Bypass 54 ND 83 570 1 54 0 X 25 Zone Bypass 55 NE 83 570 1 55 4 X 25 Zone...

Page 45: ...r 16 QJ A8 401 3 16 A C Home User 17 QK A8 401 3 17 A C Home User 18 QL A8 401 3 18 A C Home User 19 QM A8 401 3 19 A C Home User 20 QN A8 401 3 20 A C Home Short Code QO A9 408 3 0 A X 25 Home Tempor...

Page 46: ...F5 616 1 0 z X 25 Tamper 2 Alarm TP C5 137 1 0 z X 25 Tamper 2 Restore TQ C6 137 3 0 z X 25 Listen In To Follow TR FF 606 1 0 z X 25 TS TS FF 616 1 0 z X 25 TT TT FF 616 1 0 z X 25 TU TU FF 616 1 0 z...

Page 47: ...WY FF 616 1 0 z X 25 Spare WZ FF 616 1 0 z X 25 Disarming User 21 YA BD 401 1 21 8 C Disarming User 22 YB BD 401 1 22 8 C Disarming User 23 YC BD 401 1 23 8 C Disarming User 24 YD BD 401 1 24 8 C Dis...

Page 48: ...1 9 z X 25 Zone Expander Fault 10 33 FE 333 1 10 z X 25 Zone Expander Fault 11 34 FE 333 1 11 z X 25 Zone Expander Fault 12 35 FE 333 1 12 z X 25 Zone Expander Fault 13 36 FE 333 1 13 z X 25 Zone Expa...

Page 49: ...4 14 AE ALARM ZONE 15 53 53 3 A 15 15 15 AF ALARM ZONE 16 EE EE E A 16 16 16 AG RESTORAL ZONE 1 77 77 7 R 1 17 17 R1 RESTORAL ZONE 2 35 35 5 R 2 18 18 R2 RESTORAL ZONE 3 50 50 0 R 3 19 19 R3 RESTORAL...

Page 50: ...E F F Pull Station 115 3 73 3 C E G G Duct 116 3 74 4 C E H H Flame 117 3 75 5 C E D D Near Alarm 118 3 76 6 C E I I Panic 120 3 78 8 C E J J Duress 121 3 79 9 C E K K Silent 122 3 7A A C E J J Audibl...

Page 51: ...ilure 307 1 0 33 3 C E 1b 1b System shutdown 308 1 0 34 4 C E 1c 1c Battery test failure 309 1 0 35 5 C E 1d 1d Ground fault 310 1 0 36 6 C E 1e 1e Battery Missing Dead 311 1 0 37 7 C E 1f 1f Power Su...

Page 52: ...2 2 C E 2A 2A Protection loop open 371 3 0 73 3 C E 2B 2B Protection loop short 372 3 0 74 4 C E 2C 2C Fire trouble 373 3 0 75 5 C E 2D 2D Exit error alarm zone 374 1 76 6 C E s s Exit error alarm zon...

Page 53: ...CD D C E 3F 3F Legal Code Entry 462 3 0 CE E C E 3G 3G Re arm after Alarm 463 3 0 CF F C E 3H 3H Auto arm Time Extended 464 3 0 D0 0 C E 3I 3I Panic Alarm Reset 465 3 0 D1 1 C E 3J 3J Service On Off...

Page 54: ...5 5 C E 00 00 Fire Zone Walk Tested Zone Digital Comm 614 0 66 6 C E 00 00 Panic Zone Walk Tested 615 0 67 7 C E 00 00 Service Request 616 0 68 8 C E 00 00 Event Log reset 621 1 0 6D D C E 4d 4d Event...

Page 55: ...pass Zone bypass has been removed Zone or point BV Burglary Verified A burglary alarm has occurred and been verified within programmed conditions zone or point not sent Area number BX Burglary Test Bu...

Page 56: ...trouble eliminated Expander number ES Expansion Device Tamper Expansion device enclosure tamper Expansion device number ET Expansion Trouble Expansion device trouble Expander number EX External Devic...

Page 57: ...Zone or point KJ Heat Trouble Restore Trouble condition eliminated Zone or point KR Heat Restoral Alarm trouble condition has been eliminated Zone or point KS Heat Supervisory Unsafe heat detection s...

Page 58: ...point QU Emergency Unbypass Bypass has been removed Zone or point RA Remote Programmer Call Failed Transmitter failed to communicate with the remote programmer Unused RB Remote Program Begin Remote p...

Page 59: ...rouble condition has been eliminated Zone or point WS Water Supervisory Water unsafe water detection system condition Zone or point WT Water Trouble Water zone disabled by fault Zone or point WU Water...

Page 60: ...problem with the power supply Unused YQ Power Supply Restored TRANSMITTER S RECEIVER S power supply has been restored Unused YR System Battery Restoral Low battery has been corrected Unused YS Communi...

Page 61: ...el PimaGuard Installation Guide 61 bit6 bit25 INTRAC2000 bit11 MILCOLD DESK mask bit7 spare mask Repeater Formats The supported are PAF NPAF EPAF and all 4x2 compatibles Format Source format Flags Ext...

Page 62: ...to take all necessary precautions for his her safety and the protection of his her property This document may not be duplicated circulated altered modified translated reduced to any form or otherwise...