70
HUNTER-PRO 896 Installation Guide
If not, the system displays the names of the zones not tested, in the following order:
Untested Zones:
UT:Zone 12
Untested Zones:
UT: Living Room
Untested Zones:
++++++++++++++++
Untested Zones:
Burglary
ENTR
ENTR
Zone No.
Zone Name
Zone’s Partitions
Zone Type
This test is very useful for testing the system at the end of installation.
5.12.2
Single Zone Test
0
ENTR
ENTR
Tests
ENTER/NEXT/END
Single Zone Test
ENTER/NEXT/END
NEXT
Single Zone Te32
ZONE
32
Press zone no. and
ENTR
This test checks a single detector, line or wireless. To test a zone, press the designated
zone number. The first 8 zones are the outputs on the PCB and are named “on board
zone”. Pressing
displays the zone’s name, partition and type.
The process of testing a wireless zone is the same. The detector’s RSSI level is
displayed in response to receiving a transmission (see next section on how to test a
wireless zone). All other screens match.
5.12.3 Wireless
Test
0
ENTR
ENTR
NEXT
Tests
ENTER/NEXT/END
Wireless Test
ENTER/NEXT/END
Wait for Trans.
Zone 19 19
RSSI=3 (3=MAX)
X2
Zone Name
Zone Number
RSSI level:
1= Weak
2= Medium
3= Excellent
Trigger a wireless
detector. A series of
beeps will be produced by
the keypad buzzer, once a
transmission received
RSSI: Received Signal
Strength Indication
This is a wireless detector test. The purpose of the test is to check the reception level
of wireless detectors installed in the system. A transmission from a detector will be
displayed on the screen, showing the detector’s RSSI, and be registered in the memory
log. This test is useful for finding the best location for wireless detectors and their
optimal regularity.
5.12.4
Set Soak Zone
0
ENTR
ENTR
NEXT
Tests
ENTER/NEXT/END
Set Soak Zone
ENTER/NEXT/END
X3
Zone Number:
1
Entr-Conf
#-Rst
ENTR
Soak Zone
Zone 1
-1