HUNTER-PRO 896 Installation Guide
29
3.9.1
RXN-400 & RXN-410 LCD Keypads
Keypads Control
Panel
1
-
-
2
+
+
3
OUT
IN
4
IN
OUT
Figure 19 - Connecting 8 LCD keypads to control panel
To set the keypad’s ID:
1) Short JP1 legs 1 & 2 on the keypad (see figure below).
JP1
PROGRAMMING
U1
1
TAMPER
TMPR
TMPR
4
3
2+V
1-V
BUS
TAMPER
(Optional)
Terminal
block
connection
to control
panel
RJ11- Connecting to
the fast programmer
(PRG-22) and local
programming
adaptor LCL-11A
JP1:
Programming
Keypad’s ID
+
-
OUT
IN
Figure 20 - LCD keypad without back cover
2) In the following screen, enter new ID number (1 to 8):
E n t e r n e w I D : 1
3) Short JP1 legs 2 & 3 (back to the jumper’s primary state).
4) Repeat the process above for the remaining keypads. Note that each keypad must
have a unique ID number and that numbering must be consecutive.
Notes
:
1. If keypad supervision is not needed, the number of keypads connected to the
system (see section
5.2.4) and all keypads’ IDs should be set to zero.
2. Up to 8 keypads can be connected to the system, whether they are supervised or
not.