60
HUNTER-PRO 896 Installation Guide
Output type
Trip time (sec)
X7 Fire
240
X8 Special
Fire
240
X9 Panic
240
X10 Silent
Panic
240
X11 Hold
Up
240
X12 Medical
240
X13 Tamper
240
X14 Mains
Fault
9999
X15 Low
Battery
9999
X16 Phone
Fault
9999
X17 Trouble
9999
X18 Zone
Bypassed
9999
X19 GSM
Fault
9999
X20 Comm.
Fault
9999
X21 TAG
Activation
240
X22 Door
code
5
X23 W/L
Remote
5
X24 Test
5
X25 Audio
Device
60
X26 Remote
control*
60
X27
Zone Open Hold**
0 (min)
* Remote Control time defines the time an output under remote control remains
opened.
** Zone Open Hold time is an energy saving feature: use it to turn off air conditions or
lights at the end of the day.
It is a timer that works in conjunction with the ‘Zone Opened’ output type: normally,
a PCB output that is triggered by ‘Zone Opened’ output type is closed as soon as the
final zone of the output partitions is closed. But when setting the ‘Zone Open Hold’
time it will remain opened for that time, and only if no movement had been
detected by the motion detectors, the PCB output will be closed.
5.5.3 AC
Report
Delay
4
ENTR
ENTR
NEXT
X2
Timers, Counters
ENTER/NEXT/END
AC Report Delay
ENTER/NEXT/END
AC Report Delay
240 Minutes
Set the mains (AC) failure report delay time (in minutes). When mains resume the
timer resets. Time range: 0 - 250 minutes.
to save.
5.5.4
Phone Report Delay
. Set the phone failure report delay time (in minutes).