64
HUNTER-PRO 896 Installation Guide
5.8
Key #7
: Outputs Configuration
7
ENTR
ENTR
Output Configur.
ENTER/NEXT/END
External Siren
ENTER/NEXT/END
ENTR
Part. for OUT
++++++++++++++++
PD
-+
ENTR
Output Type
Output’s partitions
Output’s Polarity
External Siren
External Siren
PCB’s (physical) output
Set the system’s outputs and output type’s configuration. See section
1.4 to distinct
between the two.
The outputs can also be triggered based on the system’s partitions, i.e. be triggered
only by alarms generated in the enabled partitions.
IMPORTANT!
By default, the output types are allocated to the physical outputs, according
to the printed outputs names on the PCB. It is not advisable to change these
unless specific installation requirements.
5.8.1
PCB & Expanders Outputs
There are seven outputs on the system’s PCB: Ext. & Int. SIRENS, SMOKE, RELAY,
ON/OFF, ALARM, Audio Ctrl. The expanders' outputs are also set in this menu.
7
ENTR
Output Configur.
ENTER/NEXT/END
External Siren
ENTER/NEXT/END
p
Press
PCB/Expanders Output
X1 Internal
Siren
X2 RELAY
X3
SMOKE (reset detectors)
X4 ON/OFF
X5 ALARM
X6 Audio
Control
X7 OUT-1000
Outputs
X8 I/O-R
Outputs
X9 I/O-8
Outputs
5.8.2 Output
Types
Following, is a table of all output types by their order in the menu and the relation to
the PCB outputs. To clarify, the process of programming is as follows:
Pick the output to be programmed
pick an output type
set the
output partition/s
set the output polarity (see how further)