SDD ES PROFINET
Operating Manual SDD ES PROFINET
1003826-EN-01
22
Option
Value range
Meaning
Safety Gate
/
Status of safety gate
Actuator within the re-
sponse range
Actuator not within the
response range
Lock
/
Status of guard locking
activated
deactivated
OSSD 1&2
/
Status OSSD1 & 2 (updated automatically)
closed
open
SN#
Serial number of safety device
Ident#
Material number of safety device
Actuator#
Short name of the actuator (updated automatically)
Device Type
C, F, U
Pilz coding type
C = coded
F = fully coded
U = uniquely fully coded
Teach In Free
1-8
Number of teach-in processes remaining
Temperature in
°C
Temperature in °C
Updated by reload: this page is updated by reloading the page in the browser.
Settings
The following options are available under
Settings
:
}
Manage equipment identifier for the connected safety devices [
23]
}
Set and store GPIO values [
23]
}
Manage password for the range
Settings
(see
Set new Password [
23]
)
This is the preset login data when the device is delivered:
– User = User
– Password = 1111
Once logged in, you can log out again with logout. Logout occurs automatically
when the SDD ES PROFINET is restarted or the browser is closed.
}
Delete the list of events (see
Delete Events [
23]
)
}
The
Settings
area can be used by 2 users simultaneously.
}
Download data
The values in the areas
Settings
,
Device Info
,
Device History
and
Device Event
can be exported by clicking
Download
and saving the displayed