Pilz SDD ES PROFINET Operating Manual Download Page 2

Preface

This document is the original document.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for the user's internal purposes. Suggestions and comments for improving this documenta-
tion will be gratefully received.
Source code from third-party manufacturers or open source software has been used for
some components. The relevant licence information is available on the Internet on the Pilz
homepage.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®,
SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks
of Pilz GmbH & Co. KG in some countries.

 SD means Secure Digital

Summary of Contents for SDD ES PROFINET

Page 1: ...SDD ES PROFINET Operating Manual 1003826 EN 01 PSEN sensor technology...

Page 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Page 3: ...iption 9 Operation 9 Data structure 10 Block diagram 10 Installation 10 Commissioning 11 General wiring guidelines 11 Ethernet interfaces 11 RJ45 interfaces Ethernet 11 Requirements of the connection...

Page 4: ...Contents Operating Manual SDD ES PROFINET 1003826 EN 01 4 Dimensions in mm 27 Tecnical details 28 Order reference 30 Product 30 Accessories 30 EC declaration of conformity 31...

Page 5: ...s particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventi...

Page 6: ...T is an active subscriber Master of Safety Device Diagnostics Backlit display LEDs for Supply voltage Fieldbus interface Safety states and diagnostic information for the safety devices Error Multifunc...

Page 7: ...or connecting the signal input of the safety devices RX Input for connecting the signal output of the safety devices 1 6 Configurable inputs outputs for connecting signal inputs outputs from ad dition...

Page 8: ...s Safety related functions of the safety devices have to be evaluated separately by a safe evaluation device The following is deemed improper use in particular Any component technical or electrical mo...

Page 9: ...ided in the section entitled Safety Have a good knowledge of the generic and specialist standards applicable to the spe cific application Warranty and liability All claims to warranty and liability wi...

Page 10: ...devices List of messages and events Control system telegrams for the safety devices and responses from the safety devices The data structure including a list of the possible events is described in det...

Page 11: ...ts are provided as Ethernet interfaces via an internal autosensing switch The autosensing switch automatically detects whether data transfer is occurring at 10 Mbit s or 100 Mbit s INFORMATION The con...

Page 12: ...max 100 m NOTICE With the plug in connection please note that the data cable and connector have a limited mechanical load capacity Appropriate design measures should be used to ensure that the plug in...

Page 13: ...erating Manual SDD ES PROFINET 1003826 EN 01 13 Hub Switch Hub Switch Ethernet subscriber Ethernet subscriber PC Safety relay SDD ES PROFINET with Ethernet interface Safety relay SDD ES PROFINET with...

Page 14: ...ailsafe PSEN Y Junction Safety Device Safety Device FE I1 FS I2 FS Ethernet Set IP address There are two options Automatic assignment of the IP address with the Dynamic Host Configuration Protocol DHC...

Page 15: ...Devices Green All connected devices are enabled At least one connected device is not enabled Start up Normal operation Yellow Device data is being polled Fault Normal operation Red Fault on the SDD E...

Page 16: ...ess the multifunction switch to switch to the first menu level 1 Power Settings Device History Device Info Device Event 2 Legend 1 Display of LED supply voltage 2 Display of menu levels Operate menu T...

Page 17: ...figuration of the SDD ES PROFINET Device History Information about previous state changes of en ables on a connected safety device and status in formation Device Info Information about the connected s...

Page 18: ...to the first command via fieldbus using safety outputs of the safety control system Set to Yes Guard locking activation only via Safety Device Dia gnostics Device History menu Device History Option V...

Page 19: ...gurable inputs outputs Device n x 1 1 16 16 Device n of x connected devices Device n x Option Value range Meaning xxx Max 16 charac ters letters numbers and special charac ters Equipment identifier on...

Page 20: ...to 150 and then the oldest number is overwritten Device x Number of device Message x Display of a message or message number the messages are described in detail under Messages for safety device diagn...

Page 21: ...locking Lock Green activ ated Grey deactiv ated Status of the connected guard locking devices OSSD 1 2 Green closed Grey open Status of the connected OSSD I O Value that is read in at the GPIOs Time...

Page 22: ...Temperature in C Updated by reload this page is updated by reloading the page in the browser Settings The following options are available under Settings Manage equipment identifier for the connected s...

Page 23: ...current setting can be saved as an HTML file Click on Export Settings A DOWNLOAD LINK is displayed Right click on DOWN LOAD LINK and save the file Import settings Saved settings can be imported Click...

Page 24: ...and the directory web with FTP to the SDD ES PROFINET and save the files in the topmost directory 4 Perform a restart of SDD ES PROFINET The changed configuration is therefore adop ted Messages for sa...

Page 25: ...ator has been taught in Switch supply voltage off and then on again 0x320 Lock Guard locking could not be activ ated or deactivated Check the wiring of the control and the actuator 0x321 Lock Guard lo...

Page 26: ...the safety device OSSD2 output Check the wiring and switch the voltage off and then on again 0x908 Power please Supply voltage above the permit ted range see Technical details for safety device Reduce...

Page 27: ...SDD ES PROFINET Operating Manual SDD ES PROFINET 1003826 EN 01 27 Dimensions in mm 45 1 8 96 3 78 111 904 4 40 106 399 4 19...

Page 28: ...er 1 W Fieldbus interface Fieldbus interface PROFINET Device type Slave Maximum data length of fieldbus interface Input device 512 Byte Output 512 Byte Input output combined 512 Byte Transmission rate...

Page 29: ...ration In accordance with the standard EN 60068 2 6 Frequency 5 150 Hz Acceleration 1g Shock stress In accordance with the standard EN 60068 2 27 Acceleration 15g Duration 11 ms Protection type In acc...

Page 30: ...RMIN ALS Screw terminals plug in 540 120 SDD ES SET SPRING LOADED TERMINALS Spring loaded terminals plug in 540 121 Product type Connection X1 Connection X2 Connec tion X3 Order no PSEN Y junction M12...

Page 31: ...pin fe male connector 570 486 PSEN ml end ad apter M12 12 pin fe male connector M12 8 pin male connector 570 487 EC declaration of conformity This These product s fulfil the requirements of the low v...

Page 32: ...etyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document de...

Reviews: