SDD ES PROFINET
Operating Manual SDD ES PROFINET
1003826-EN-01
10
}
Device data
– Material number, serial number, product version, actuator ID, …
}
Configuration data
– Behaviour of the control of safety devices with guard locking (control of the guard
locking via SDD can be switched on and off on PROFINET and ETH using Autoinit)
Communication with connected control systems or control elements is via the bus interface
PROFINET.
Data structure
The input and output data is divided into the following data areas:
}
Data for the overall system and for the SDD ES PROFINET
}
Data for the connected safety devices
}
List of messages and events
}
Control system telegrams for the safety devices and responses from the safety devices
The data structure, including a list of the possible events, is described in detail in the Sys-
tem Description "Safety Device Diagnostics".
The messages are described in
Messages for safety device diagnostics [
24]
.
Block diagram
SSD In
SSD Out
Power
PROFINET
Rx
Tx
1
3
2
4
6
5
Configurable
Input/Output
24 V 0 V
Installation
}
The safety relay should be installed in a control cabinet with a protection type of at least
IP54.
}
Use the notch on the rear of the unit to attach it to a DIN rail (35 mm).
}
When installed vertically: Secure the unit by using a fixing element (e.g. retaining
bracket or end angle).
}
Push the device upwards or downwards before lifting it from the DIN rail.