SDD ES PROFINET
Operating Manual SDD ES PROFINET
1003826-EN-01
20
Option
Value range
Meaning
INPUT2
/
Status Input 2
Coding
C, F, U
Pilz coding type
(*1)
C = coded, F = fully coded, U = uniquely fully coded
TeachIn free
1-8
Number of teach-in processes remaining
(*1)
Temp °C
Temperature of a safety device in °C. The temper-
ature of one safety device is updated every two
minutes; with 16 safety devices, for example, the
temperature of the first safety device is updated
every 32 minutes.
Act.#
Actuator short name
Ident#
Material number of safety device
(*1)
SN#
Serial number of safety device
(*1)
(*1)
Value on restart
Device Event menu
Device Event
Option
Meaning
Event Nr. x
Display of consecutive event numbers (event num-
ber is incremented up to 150 and then the oldest
number is overwritten)
Device x
Number of device
Message # x
Display of a message or message number (the
messages are described in detail under
Messages
for safety device diagnostics [
24]
)
Web server
A web server is implemented in the fieldbus module SDD ES PROFINET. This can be used
to poll data from the SDD.
}
The web server is started once the SDD ES PROFINET is connected to the supply
voltage.
}
The web server is intended for use with Internet Explorer or Firefox.
}
Make sure that Javascript and Cookies are enabled in your browser's security settings.
Start of the web server
1. Connect the SDD ES PROFINET to the PC.
2. Call up the HTML page:
–
http://192.168.0.xxx
– For xxx, enter the value that you have set as the last byte of the IP address.
3. Enter the user name and password correctly and log on to the web server.
4. Select the option you require in the overview and then follow the instructions.