Electrical data
Switching voltage
24 V
Internal resistance safety contacts
0 Ohm
Internal resistance auxiliary contact
0 Ohm
Max. switching current, safety contacts
0,14 A
Max. breaking capacity, safety contacts
4 W
Max. switching current, auxiliary contacts
140 mA
Utilisation category in accordance with EN 60947-1
DC-12
Conventional thermal current auxiliary contact
0,1 A
Max. continuous current safety contacts
0,1 A
Times
Reaction time (actuator removed)
2 ms
Environmental data
Ambient temperature
Temperature range
-25 - 120 °C
Max. temperature in accordance with UL
-25 - 105 °C
Climatic suitability
In accordance with the standard
IEC 60068-2-30
Humidity
90 % r. h. at 40 °C
Max. operating height above sea level
4000 m
EMC
EN 60947-5-3
Vibration
In accordance with the standard
EN 60947-5-2
Frequency
10 - 55 Hz
Amplitude
1 mm
Shock stress
Acceleration
30g
Duration
11 ms
Airgap creepage
Pollution degree
3
Rated insulation voltage
30 V
Rated impulse withstand voltage
0,8 kV
Protection type
Housing
IP67, IP69
Mechanical data
Actuator 1
PSEN ma1.3-08 VA
Typ. Hysteresis
3 mm
Operating distances
Assured operating distance Sao
8 mm
Min. operating distance Somin
0,5 mm
Typical operating distance So
10 mm
Assured release distance Sar
18 mm
Typical release distance Sr
13 mm
Repetition accuracy switching distances
5 %
Min. distance between safety switches
25 mm