CAUTION!

Potential loss of safety function due to changed device properties

The unit's properties may be affected if installed in an environment contain-
ing electrically or magnetically conductive material.

– Please check the operating distances and the assured release dis-

tance.

CAUTION!

Possible loss of the safety function by changing the release distance
S

ar

 with non-flush installation

Installing the safety switch non-flush within electrically or magnetically con-
ductive material, the value for the assured release distance 

S

ar

 can change.

– Check the assured release distance 

S

ar.

}

Safety switches and actuators must be positioned so that they are secured against a
change of position.

}

The safety switch and actuator should only be secured using screws and nuts made of
non-magnetic material (e.g. brass or stainless steel).

}

Avoid the risk of damages from foreseeable external influences by attaching the safety
switch and actuator. If necessary, safety switch and actuator have to be protected.

INFORMATION

Protect the actuator from unauthorised removal (e.g. via a screw lock or
concealed installation) and from contamination.

}

Prevent self-loosening of the fastening elements of safety switch and actuator.

}

The fastening of safety switch and actuator has to be sufficiently stable to ensure the
proper operation of the safety switch and the actuator.

}

The distance between two safety switches must be maintained (see 

Technical

details [

 18]

).

}

Safety switches and actuators

Should be kept away from iron swarf

Should not be exposed to strong magnetic fields

}

Prevent the safety switch and actuator being exposed to heavy shock or vibration.

}

Make sure that the safety switch and actuator cannot be used as an end stop.

}

Circumvention of the safety switch in a reasonably foreseeable manner must be pre-
vented.

}

Please note the installation measures in accordance with EN ISO 14119 for a proximity
switch type 4 with coding level Low.

Summary of Contents for PSEN ma1.3-22 M12/8 VA

Page 1: ...PSEN ma1 3 22 M12 8 VA Operating Manual 1004511 EN 02 PSEN sensor technology...

Page 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Page 3: ...y 6 Disposal 6 For your safety 7 Unit features 7 Function description 7 Block diagram 8 Operating distances 8 Lateral and vertical offset 9 Wiring 9 Pin assignment 10 Requirements and connection to ev...

Page 4: ...ion that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicate...

Page 5: ...trol cabinet terminal PSEN ix0 F1 mag see Order reference for accessories 22 and the suitable evaluation devices The following is deemed improper use in particular Any component technical or electrica...

Page 6: ...state of the art and the applicable national European and international laws directives and standards It is the company s responsibility only to employ personnel who Are familiar with the basic regula...

Page 7: ...the connector s protective cap until you are just about to connect the unit This will prevent potential contamination Unit features The actuator PSEN ma1 3 08 VA belongs to the safety switch Coded ac...

Page 8: ...22 and a connected evaluation device If the actuator is within the response range safety gate closed the safety contacts and the auxiliary contact on the safety switch are closed Block diagram Actuato...

Page 9: ...2 5 8 2 7 2 6 6 5 1 4 5 8 5 1 3 2 The stated values are valid at a temperature of 20 C Wiring Information given in the Technical details 18 must be followed Calculation of the max cable length lmax R...

Page 10: ...e provided via a Class 2 power supply Pin assignment NOTICE The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory The safety switch is shown in an un...

Page 11: ...PLC for safety gate monitoring with function block FS_SafetyGate The correct connection to the respective evaluation device is described in the operating manual for the evaluation device Make sure tha...

Page 12: ...y times of the evaluation device s operating manual for the relevant evaluation device Y1 Y8 A2 A1 11 12 14 Y2 Y3 Y4 Y5 Y6 Y9 1 2 3 4 13 23 24 21 22 31 33 34 32 41 43 44 42 A1 A2 1 2 3 4 11 12 14 13 1...

Page 13: ...EN 02 13 Examples for connection to Pilz evaluation devices Application in series connections S21 S22 S11 S12 1 2 3 4 5 6 7 8 PNOZ s3 PSENmag PSEN ix1 Yellow White Pink Green 1 2 3 4 T0 I0 T1 I1 1 2...

Page 14: ...2 3 4 5 6 7 8 PNOZmulti PSENmag PSEN ix0 F1 mag 12 22 11 21 Yellow White Pink Green Installation The unit can be installed in any position Safety switches and actuators must be in stalled so that the...

Page 15: ...steel Avoid the risk of damages from foreseeable external influences by attaching the safety switch and actuator If necessary safety switch and actuator have to be protected INFORMATION Protect the ac...

Page 16: ...is complied with see Technical details Application in series connections Install the interface PSEN ix1 in the control cabinet and wire the interface with the eval uation device see Wiring 10 Applica...

Page 17: ...tions Installation 15 Operating distances may deviate if other arrangements are used Note the maximum permitted lateral and vertical offset see Operating distances and Lateral and vertical offset 8 Ap...

Page 18: ...ns Always test the function with the control cabinet terminal PSEN ix0 F1 mag and con nected evaluation device Dimensions in mm Safety switch 60 36 1 M12x1 Actuator PSEN ma1 3 08 VA 25 19 M12x1 Techni...

Page 19: ...perature in accordance with UL 25 105 C Climatic suitability In accordance with the standard IEC 60068 2 30 Humidity 90 r h at 40 C Max operating height above sea level 4000 m EMC EN 60947 5 3 Vibrati...

Page 20: ...mm Width 12 mm Depth 25 mm Weight of safety switch 20 g Weight of actuator 10 g Weight 30 g Where standards are undated the 2017 09 latest editions shall apply Safety characteristic data NOTICE You m...

Page 21: ...le with without crimp connector 0 08 2 5 mm 28 14 AWG Stripping length with spring loaded terminals 5 6 mm Dimensions Height 56 mm Width 7 mm Depth 91 mm Weight 25 g Order reference System Product typ...

Page 22: ...Interface for 4 PSEN 1 Interface PSEN ix1 for connecting and evaluating several safety switches PSEN ma 535 120 Single connection Product type Features Order no PSEN ix0 F1 mag Control cabinet termina...

Page 23: ...NET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depen...

Reviews: