PSEN ma1.3-22 M12/8 VA
Operating Manual PSEN ma1.3-22 M12/8 VA
1004511-EN-02
17
Installation with actuator PSEN ma1.3-08/VA
Sensing face
Slide the actuator through the hole in the
mounting surface with the sensing face to-
wards the safety switch.
Attach the actuator using 2 M12x1
hexagonal nuts.
Also note the max. torque setting (see
).
Adjustment
Application in series connections
}
The safety switch may only be used with the corresponding actuator PSEN ma1.3-08
VA.
}
Always test the function with the PSEN ix1 interface and connected evaluation device.
}
The stated operating distances (see
) only apply when the
safety switch and actuator are installed according to the specifications
. Operating distances may deviate if other arrangements are used.
Note the maximum permitted lateral and vertical offset (see
Application in single connections
}
The safety switch may only be used with the corresponding actuator PSEN ma1.3-08
VA.
}
Always test the function with the control cabinet terminal PSEN ix0 F1 mag and con-
nected evaluation device.
}
The stated operating distances (see
) only apply when the
safety switch and actuator are installed according to the specifications
. Operating distances may deviate if other arrangements are used.
Note the maximum permitted lateral and vertical offset (see
Periodic test
}
Carry out a monthly function test on the safety switch and actuator.
}
The safety function may only be checked by qualified personnel.