background image

PSEN ma1.3-22 M12/8 VA

Operating Manual PSEN ma1.3-22 M12/8 VA
1004511-EN-02

11

Certified Pilz evaluation devices are, for example:

}

PNOZelog for safety gate monitoring

PNOZ e1p, PNOZ e1.1p, PNOZ e1vp

PNOZ e5.11p

PNOZ e6vp, PNOZ e6.1p

}

PNOZpower for safety gate monitoring

PNOZ p1p, PNOZ p1vp

}

PNOZsigma for safety gate monitoring:

PNOZ s3

PNOZ s4

PNOZ s5

}

PNOZ X for safety gate monitoring

PNOZ X2, PNOZ X2.5P, PNOZ X2.7P, PNOZ X2.8P, PNOZ X2.9P, PNOZ X2C

PNOZ X3, PNOZ X3.1, PNOZ X3P, PNOZ X3.10P

PNOZ X4

PNOZ X5, PNOZ X5J

PNOZ Ex

}

PNOZmulti for safety gate monitoring
Configure the switch in the PNOZmulti Configurator with switch type 3.

}

PSS for safety gate monitoring with standard function block SB064, SB066 or
FS_Safety Gate

}

PSSuniversal PLC for safety gate monitoring with function block FS_SafetyGate

The correct connection to the respective evaluation device is described in the operating
manual for the evaluation device. Make sure that the connection is made in accordance
with the specifications in the operating manual for the selected evaluation device.

Defined properties of evaluation devices:

}

2-channel with feasibility monitoring

}

Open circuit monitoring of the safety switch is performed

}

Inputs and outputs on the evaluation device must fulfil the requirements of IEC 61131,
Type 3

}

Technical data of the evaluation device must fulfil the requirements in the 

Technical

details [

 18]

 of PSEN ma1.3-22 M12/8 VA

Always comply with the max. switching current safety contacts of PSEN ma1.3-22
M12/8 VA.

}

Outputs at the evaluation device must only be switched on again when both reed con-
tacts at the safety switch have been opened and closed (partial operation lock)

Summary of Contents for PSEN ma1.3-22 M12/8 VA

Page 1: ...PSEN ma1 3 22 M12 8 VA Operating Manual 1004511 EN 02 PSEN sensor technology...

Page 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Page 3: ...y 6 Disposal 6 For your safety 7 Unit features 7 Function description 7 Block diagram 8 Operating distances 8 Lateral and vertical offset 9 Wiring 9 Pin assignment 10 Requirements and connection to ev...

Page 4: ...ion that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicate...

Page 5: ...trol cabinet terminal PSEN ix0 F1 mag see Order reference for accessories 22 and the suitable evaluation devices The following is deemed improper use in particular Any component technical or electrica...

Page 6: ...state of the art and the applicable national European and international laws directives and standards It is the company s responsibility only to employ personnel who Are familiar with the basic regula...

Page 7: ...the connector s protective cap until you are just about to connect the unit This will prevent potential contamination Unit features The actuator PSEN ma1 3 08 VA belongs to the safety switch Coded ac...

Page 8: ...22 and a connected evaluation device If the actuator is within the response range safety gate closed the safety contacts and the auxiliary contact on the safety switch are closed Block diagram Actuato...

Page 9: ...2 5 8 2 7 2 6 6 5 1 4 5 8 5 1 3 2 The stated values are valid at a temperature of 20 C Wiring Information given in the Technical details 18 must be followed Calculation of the max cable length lmax R...

Page 10: ...e provided via a Class 2 power supply Pin assignment NOTICE The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory The safety switch is shown in an un...

Page 11: ...PLC for safety gate monitoring with function block FS_SafetyGate The correct connection to the respective evaluation device is described in the operating manual for the evaluation device Make sure tha...

Page 12: ...y times of the evaluation device s operating manual for the relevant evaluation device Y1 Y8 A2 A1 11 12 14 Y2 Y3 Y4 Y5 Y6 Y9 1 2 3 4 13 23 24 21 22 31 33 34 32 41 43 44 42 A1 A2 1 2 3 4 11 12 14 13 1...

Page 13: ...EN 02 13 Examples for connection to Pilz evaluation devices Application in series connections S21 S22 S11 S12 1 2 3 4 5 6 7 8 PNOZ s3 PSENmag PSEN ix1 Yellow White Pink Green 1 2 3 4 T0 I0 T1 I1 1 2...

Page 14: ...2 3 4 5 6 7 8 PNOZmulti PSENmag PSEN ix0 F1 mag 12 22 11 21 Yellow White Pink Green Installation The unit can be installed in any position Safety switches and actuators must be in stalled so that the...

Page 15: ...steel Avoid the risk of damages from foreseeable external influences by attaching the safety switch and actuator If necessary safety switch and actuator have to be protected INFORMATION Protect the ac...

Page 16: ...is complied with see Technical details Application in series connections Install the interface PSEN ix1 in the control cabinet and wire the interface with the eval uation device see Wiring 10 Applica...

Page 17: ...tions Installation 15 Operating distances may deviate if other arrangements are used Note the maximum permitted lateral and vertical offset see Operating distances and Lateral and vertical offset 8 Ap...

Page 18: ...ns Always test the function with the control cabinet terminal PSEN ix0 F1 mag and con nected evaluation device Dimensions in mm Safety switch 60 36 1 M12x1 Actuator PSEN ma1 3 08 VA 25 19 M12x1 Techni...

Page 19: ...perature in accordance with UL 25 105 C Climatic suitability In accordance with the standard IEC 60068 2 30 Humidity 90 r h at 40 C Max operating height above sea level 4000 m EMC EN 60947 5 3 Vibrati...

Page 20: ...mm Width 12 mm Depth 25 mm Weight of safety switch 20 g Weight of actuator 10 g Weight 30 g Where standards are undated the 2017 09 latest editions shall apply Safety characteristic data NOTICE You m...

Page 21: ...le with without crimp connector 0 08 2 5 mm 28 14 AWG Stripping length with spring loaded terminals 5 6 mm Dimensions Height 56 mm Width 7 mm Depth 91 mm Weight 25 g Order reference System Product typ...

Page 22: ...Interface for 4 PSEN 1 Interface PSEN ix1 for connecting and evaluating several safety switches PSEN ma 535 120 Single connection Product type Features Order no PSEN ix0 F1 mag Control cabinet termina...

Page 23: ...NET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depen...

Reviews: