![Pilz PSEN cs2.13p ATEX Operating Manual Download Page 28](http://html1.mh-extra.com/html/pilz/psen-cs2-13p-atex/psen-cs2-13p-atex_operating-manual_1556967028.webp)
PSEN cs2.13p ATEX
Operating Manual PSEN cs2.13p ATEX
21133-EN-17
| 28
}
T
M
is the maximum mission time in accordance with EN ISO 13849-1. The value also ap-
plies as the retest interval in accordance with EN 61508-6 and IEC 61511 and as the
proof test interval and mission time in accordance with EN 62061.
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are
not
identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
Supplementary data
Radio approval
USA/Canada
FCC ID:
IC:
FCC/IC-Requirements:
This product complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standards.
Operation is subject to the following two conditions:
1) this product may not cause harmful interference, and
2) this product must accept any interference received, including interference that may cause undesired operation.
Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
Le présent produit est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
(1) le produit ne doit pas produire de brouillage, et
(2) l'utilisateur de le produit doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
VT8-PSENCS1
7482A-PSENCS1
Order reference
System
Product type
Features
Connection type
Order no.
PSEN cs2.13p/PSEN cs2.1
Safety switch with transpon-
der technology, fully coded,
with actuator with assured
operating distance 15 mm
8-pin M12 connector
540 105
PSEN cs2.1
Actuator with transponder
technology
540 180