Fault indicator
:
}
"Input" LED lights up yellow: the signal switches from high to low at one input, while a
high signal remains on the other input (partial operation).
Remedy: Open both channels of the input circuit.
}
"Power/Fault" LED lights up red: Error message
Remedy: Rectify fault and interrupt power supply.
Please note the different times for
}
The switch-on delay after UB is applied
}
The recovery time of the sensor and evaluation device.
Dimensions in mm
Safety switch
5,1
1
61
45
72
21,5
74
2
0
5
,5
3
0
4
0
2
0
Actuator
30
40
5,3
3
0
4
0
0
,5
4
1
1
Technical details
General
Certifications
ATEX, CE, EAC (Eurasian), ECOLAB, FCC, IC,
TÜV, cULus Listed, electrosuisse
Sensor's mode of operation
Transponder