PSEN cs2.13p ATEX
Operating Manual PSEN cs2.13p ATEX
21133-EN-17
| 14
Connection to evaluation devices
Make sure that the selected evaluation device has the following properties:
}
2-channel with feasibility monitoring
}
OSSD signals are evaluated
Please note:
}
The use of Safety Device Diagnostics is described in the System Description "Safety
Device Diagnostics".
CAUTION!
Do not connect the signal output to 0 V!
If the signal output Y32 is connected to 0 V, the safety switch may be dam-
aged as a result. Connect the signal output Y32 to a consumer, e.g. to the
input on a control system, or leave the signal output unconnected. Also note
the max. current (see
Technical details [
24]
).
Connection diagram, single connection without SDD
Actuator
Safety switch
Evaluation device
Ex area
Non-Ex area