1. Drill holes (for M5 screws) in the mounting surface to secure the actuator and sensor
(see
Dimensions in mm [
24]
).
2. Use a screw to fix the sensor to the mounting surface.
Make sure that the sensor marking that is be used for operation can be operated using
the actuator from the right side.
3. Do not fully tighten the second screw on the safety switch.
4. Use a screw to fix the actuator to the mounting surface.
Make sure that the actuator with the printed side points towards the marking on the
sensor.
5. Do not fully tighten the second screw on the actuator.
6. Align the safety switch and tighten the screws.
7. Align the actuator and tighten the screws.
Periodic test
}
Make sure that the work is
not
performed in an explosive atmosphere.
}
Carry out a monthly function test on the safety switch and actuator.
}
Always test the function with a connected evaluation device.
}
The safety function may only be checked by qualified personnel.
}
Refer to the notes on checking the safety switch in EN 60079‑17 and EN 60079‑19.
Adjustment
}
The stated operating distances (see
Technical details [
24]
) only apply when the
safety switch and actuator are installed facing each other in parallel. Operating distances
may deviate if other arrangements are used.
}
Note the maximum permitted lateral and vertical offset (see
Operating distances [
11]
and
Lateral and vertical offset [
12]
).
Operation
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
Status indicators
:
}
"Power/Fault" LED lights up green: The unit is ready for operation
}
"Safety Gate" LED lights up yellow: Actuator is within the response range
}
"Input" LED lights up yellow: There is a high signal at both inputs