9 Interfaces
Installation manual PMCprimo Drive2
Page
77
9.12
Virtual inputs and outputs
In addition to the real digital inputs and outputs there are 16 virtual inputs and 16 virtual outputs on
each PMCprimo Drive2 system.
The virtual inputs and outputs don’t have any terminals. But all input and output commands are
available (see PMCprimo programming manual).
9.12.1 Terms
Virtual inputs: E3:1 – E3:8 / E4:1 – E4:8
Virtual outputs (O2:1 – O2:8) / O3:1 – O3:8 / O4:1 – O4:8
The virtual inputs an outputs are connected (internal) together as shown below:
Outputs O2:x to input E3:x
Outputs O3:x to input E3:x
Outputs O4:x to input E4:x
9.12.2 Application
example
You define a position output on the virtual output (e.g.0.3:2).
If you define an input function on input 0.3:2, this program will be executed each time the output
0.3:2 is set. You don’t need any wiring!
For further details see PMCprimo programming manual.