Table 6 Time Limited Inspection Requirements
Task number
Item Name
Task Description
Interval
Data Module Refer-
ence
53-00/93
Structure around win-
dows
Examine
Mild Corrosive Envi-
ronment: 6000 FH or
72 Months
Moderate Corrosive
Environment: 4000
FH or 48 Months
Severe Corrosive En-
vironment: 2000 FH
or 24 Months
Note
Local conditions may
be more or less se-
vere. Based on field
experience the inter-
val can be adjusted
to more or less fre-
quent, until an effec-
tive interval can be
set.
-
53-00/94
Door frames and
emergency exit frame
Examine. If insulation
is installed in the door
frames and is wet,
remove and discard
it (no longer installed
on production)
Mild Corrosive Envi-
ronment: 6000 FH or
72 Months
Moderate Corrosive
Environment: 4000
FH or 48 Months
Severe Corrosive En-
vironment: 2000 FH
or 24 Months
Note
Local conditions may
be more or less se-
vere. Based on field
experience the inter-
val can be adjusted
to more or less fre-
quent, until an effec-
tive interval can be
set.
-
53-30/342
Static ports critical
area (RVSM aircraft)
Inspection/check
12 Months
55-10/95
Horizontal stabilizer
internal surfaces
and horizontal/verti-
cal stabilizer interface
Deleted from sched-
uled maintenance
-
-
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 27 MSN 545, 1001-1719, 1721-1942
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-05-10-20-00A-281A-A
UNCLASSIFIED
07.02.2022 Page 10