RSE METER
Use and Maintenance Manual
PM Version
ENGLISH
ISV065UTE
Rev.8
Date of issue
04/06/2014
Revision
8
Revision date
20/07/2015
Page 7 of 32
Manual
- User
Manual:
The user manual and the use and maintenance manual are available for download on the website www.fiorentini.com
Certificates
The EC declaration of conformity is enclosed to the transport documents of the instrument
2. Safety instructions
RSE is an intrinsically safe device suitable for use in hazardous areas classified as Zone 2 Group IIB. The minimum installation category
is ATEX Category II 3G. The harmonized CENELEC standards relevant to the compliance with the EHSR requirements (Essential
Health and Safety Requirements) of the ATEX Directive are EN 60079-0 and EN 60079-11.
This device is designed to comply with the requirements of the type of protection Ex ic IIA T3 Gc, ambient temperature range -25
°
/55
°
C
and ATEX category II 3G.
2.1. Electrostatic
discharges
This device is approved for installation in areas with low explosion risk (risk only for short periods). In these areas, sparks produced from
electrostatic discharges could generate explosions in extreme cases. Although during normal operation there is no presence of
dangerous potentials on the device, the use of dissipative footwear and of a damp cloth (% > 65%) is recommended during the
installation/maintenance. Further information can be found in CEI 50404.
Pietro Fiorentini SpA denies all liabilities resulting from the risks and consequences caused by the non-
compliance with these provisions
2.2. Connecting to other devices
There is no RSE connection with external devices.
RSE can connect, using the ZVEI optical port, to devices for the communication of data and commands useful for configuration and
maintenance of the device.
RSE can connect, using the GSM modem/wireless radio port, to local and/or remote devices for the communication of the data and
commands useful for configuration, management, and maintenance of the device.
2.3. Feeding
devices
RSE can be powered exclusively by a special approved battery pack.
As a matter of fat, the battery pack is a proprietary assembly consisting of a lithium battery and a cable ending with a special connector,
coated by a protective sheath.
The battery pack is a device certified for exclusive use with the RSE device and it is the only permissible power supply device.
The connector of the battery pack is polarized in such a way as to fit only in the connector specifically provided for on the device,
observing the correct polarity.
During the installation or use of this instrument, it is
advisable to take steps to assure protection
against electrostatic discharges.
Caution!
Use only batteries of the type and model complying with the original.