RSE METER
Use and Maintenance Manual
PM Version
ENGLISH
ISV065UTE
Rev.8
Date of issue
04/06/2014
Revision
8
Revision date
20/07/2015
Page 31 of 32
10. Technical characteristics
10.1. General features
Parameter
Features
Enclosure
Main body:
Transparent cover:
Polycarbonate
Polycarbonate
Protection degree
IP 55
Dimensions (overall)
RSE/2001 LA
RSE/2.4
Max 223(H) x 190(L) x 172,5(P)
Max 246(H) x 341,5(L) x 179(P)
Distance
RSE/2001 LA
RSE/2.4
110 mm
250 mm
Type of gas
Methane gas, town gas, propane and
butane
gas from the first to the third family
UNI EN
437:2003
Operating pressure
0.5 bar
Display
Black and white LCD with segments
Resistance to high temperatures "T"
Resistance to high temperatures
EN
1359:1998+A1:2006,
paragraph
6.5.5
Keyboard 3-front
operator
keys
Operating/storage temperature
-25
°
C to +55
°
C / -25
°
C to +60
°
C
Certifications
Atex (Ex ic 3G IIB T3 Gc), MID
Metrological battery
Type:
Format:
Autonomy:
3.6 V lithium battery
Size C
>15 years
Transmission battery
Type:
Format:
Autonomy:
3.6 V lithium battery
Size C
>15 years
Microprocessor STM32L152
32
bit
Code memory
384 Kbyte of Flash type
Data memory
Type:
Data memory
EEPROM 12 Kbyte
>20 years
Real Time Clock
RTC always active
Accuracy according to EN62054-21
Accuracy
Accuracy class 1.5/1
According to MID
(*) Operating conditions
Ambient temperature
Ta min (-25
°
C)
Flow rate
Max
Use of user interface
5 minutes per month
Valve control
1 cycle per year
Code update
2 every 15 years