7.1.16. Status of the device
Abbreviation
SD
Format
1 digit
–
Possible values:
-2
production
-1
factory
0 device
configured
1
device under maintenance
3
device not configured
Unit
-
Pressing Enter
E
Pressing the central button, access is granted to the maintenance menu.
The menu structure is shown below
2 decimal digits define the menu id
2 decimal digits define the operation id
2 decimal digits define the operation result
To perform the maintenance test, if allowed, it is necessary to press the central button.
Here below there is a list of submenus:
menu id
operation
result
Description
01 01 00-01
ZVEI
port
status
00 = disabled
01 = enabled
01
02
00-01-02
Enabling the ZVEI port.
00 = operation not yet preformed
01 = operation performed successfully
02 = operation failed
01
03
00-01-02
Disabling the ZVEI port.
00 = operation not yet preformed
01 = operation performed successfully
02 = operation failed
02
01
00-01
Counting resolution status
00 = Normal resolution
01 = Resolution subject to testing
02
02
00-01-02
Setting of the counting resolution
00 = operation not yet preformed
01 = operation performed successfully
02 = operation failed
02
03
00-01-02
Setting of the normal resolution
00 = operation not yet preformed
01 = operation performed successfully
02 = operation failed
03
-
-
Display of the read temperature
04
-
00-07
Setting of the display contrast.
Press enter, and then the up/down keys to select the desired
contrast value for the LCD display; then, press enter to
confirm.
05
01
-
Reserved – factory diagnostic
05
02
-
Reserved - factory diagnostic
06 01 00-01-02-03
PM1
affiliation
status
00 = PM1 off / Waiting affiliation
01 = Affiliation in progress
02 =Affiliation failed
03 = Affiliated
06
02
00-01-02
Start PM1 affiliation
00 = ready to start (“Enter” turns PM1 on, if it is off, and starts
the affiliation)
01 = Affiliation in progress (radio icon flashing)
02 = Affiliation already started
99 - - Exit
Press enter to close the maintenance menu and return to the
main menu.
Legal relevance
NO
The menu 6 allows displaying the current status of the PM1 affiliation procedure (menu 06 01) and the related
enabling (menu 06 02), by pressing the "Enter" key. The procedure allows turning on the PM1 radio section and
simultaneously initiating the affiliation proceedings (SND-IR). The procedure can be restarted until a
confirmation message is received for the first time (CNF-IR).