Command
Parameter
Answer
Description
gwidthmax
--
pulse width in
µs
Outputs the maximum pulse width
sreprate
repetition rate
in Hz
repetition rate
in Hz
Sets the repetition rate to the
indicated value
greprate
--
repetition rate
in Hz
Outputs the present repetition rate
grepratemin --
repetition rate
in Hz
Outputs the min. repetition rate
grepratemax --
repetition rate
in Hz
Outputs the max. repetition rate
strgmode
0 .. 2
0 .. 2
Sets the trigger mode to the
indicated value:
0: external trigger input
1: internal trigger
2: cw mode
gtrgmode
--
0 .. 2
Outputs the current trigger mode
gtempoff
--
--
Outputs the shutdown temperature
gtempmax
--
--
Outputs the shutdown temperature
gtemphys
--
--
Outputs the temperature hysterere, at
which the driver can be re-enabled
after shutdown
gtempwrn
--
--
Outputs the warning temperature at
which the driver will show a
warning
gtemp
--
--
Outputs the actual temperature
enautoload
--
--
Enables the automatic loading of
default values on power-on
disautoload --
--
Disables the automatic loading of
default values on power-on
on
--
--
Enables the current output.
Internally ANDed with the enable
signal
off
--
--
Disables the current output.
Internally ANDed with the enable
signal
glstat
--
--
Outputs the content of the LSTAT
register.
slstat
32 bit number
32 bit number
Sets the LSTAT register to the given
value. Outputs the new value.