Commands for the LDP-C / CW
The following table contains a command reference for the LDP-C/CW series.
Command
Parameter
Answer
Description
gserial
--
serial number
Returns the device serial number
ps
--
current settings Prints out an overview of all settings
loaddef
--
--
Loads previously saved settings
savedef
--
--
Saves the current settings as defaults
ghwver
--
hardware
version
Prints out the hardware version
gswver
--
software
version
Prints out the software version
scur
Current in A
Current in A
Sets the pulse current to the indicated
value. A dot is used as decimal point. No
more then on decimal place is used! (12.22
is the same as 12.2)
gcur
--
Current in A
Outputs the present output current
gcurmin
--
Current in A
Outputs the minimum output current
gcurmax
--
Current in A
Outputs the maximum output current
scurlimit
Current in A
Current in A
Sets the maximum pulse current to the
indicated value. This value determines the
maximum aviable current for the scur
command. A dot is used as decimal point.
No more then on decimal place is used!
(12.22 is the same as 12.2)
gcurlimit
--
Current in A
Outputs the present current limit
gcurlimitmin --
Current in A
Outputs the minimum current limit
gcurlimitmax --
Current in A
Outputs the maximum current limit
curext
--
0/1
Switches to external current setpoint
curint
--
0/1
Switches to internal current setpoint
swidth
pulse width in
µs
pulse width in
µs
Sets the pulse width to the indicated value.
A dot is used as decimal point. No more
then one decimal place is used!
gwidth
--
pulse width in
µs
Outputs the present pulse width
gwidthmin
--
pulse width in
µs
Outputs the minimum pulse width