CAUTION
Risk of crushing by moving parts!
Risk of minor injuries from crushing between the moving parts of the L-417.099232B or the
load and a fixed part or obstacle.
►
Use safeguards to protect limbs areas where they could be caught by moving parts.
►
Observe the safety distances in accordance with DIN EN ISO 13857 when installing
protective structures.
NOTICE
Damage due to collisions!
Collisions can damage the L-417.099232B, the load to be moved, and the surroundings.
►
Make sure that collisions are not possible between the L-417.099232B, the load to be
moved, and the surroundings in the motion range of the L-417.099232B.
►
Do not place any cables or other objects in areas where they could be caught by moving
parts.
NOTICE
Excessively long screws and locating pins
Screws and locating pins that are inserted too deeply can damage the L-417.099232B.
►
Pay attention to the
depth of the mounting and locating holes (p. 30)
in the
L-417.099232B.
►
Only use screws and locating pins of the correct length for the respective mounting holes.
Mounting the L-417.099232B on a Surface
1. If necessary: Insert the locating pins into the corresponding holes in the surface.
2. Align the L-417.099232B on the surface so that the corresponding mounting holes in the
L-417.099232B and the surface are aligned.
3. Place the L-417.099232B onto the surface so that the locating pins can be inserted into the
corresponding locating holes of the L-417.099232B.
4. If necessary: Allow access to the mounting holes in the base body of the L-417.099232B.
Possible measures:
■
Temporary
startup of the L-417.099232B (p. 18)
and commanding the motion platform
to a suitable position
■
Push the motion platform by hand (p. 20)
5. Insert the screws into all accessible mounting holes and tighten.
6. If necessary: Repeat steps 4 to 5 for all concealed mounting holes.
7. Check that the L-417.099232B is fixed firmly to the surface.
6.2
Connecting the L-417.099232B to the Protective Earth Conductor
The L-417.099232B must be connected to the protective earth conductor via the drive
connector.
It is only necessary to connect the L-417.099232B's base body to the protective earth
conductor when both of the following conditions are met:
■
The load on the motion platform must be connected to the protective earth conductor, but
it is not possible to connect the protective earth conductor directly.
■
The load and the motion platform are connected conductively to each other.
6 INSTALLATION
L417M0004EN
‒
11/21/2018
14
M O T I O N | P O S I T I O N I N G