The phyCORE-MPC5200B tiny on the Development Board
©
PHYTEC Messtechnik GmbH 2006 L-678e_0
57
+5 VDC
GND
≥
1500 mA
Center Hole
1.3 mm
3.5 mm
--
+
Polarity:
Figure 14: Connecting the Supply Voltage at X1
Caution:
When using this function, the following jumper settings are not
allowed:
Jumper
Setting
Description
2 + 3
5 V as primary main supply voltage
for the phyCORE-MPC5200B tiny
JP9
open
phyCORE-MPC5200B tiny not connected to
primary main supply voltage
2 + 3
5 V as secondary main supply voltage
for the phyCORE-MPC5200B tiny
JP16
open
phyCORE-MPC5200B tiny not connected to
secondary main supply voltage
Table 15:
JP9, JP16 Improper Jumper Settings for the Main Supply Voltages
Setting Jumper JP9 to position 2+3 configures a primary main power
supply to the phyCORE-MPC5200B tiny of 5 V which could destroy
the module. Setting Jumper JP16 to position 2+3 configures a
secondary main power supply to the phyCORE-MPC5200B tiny of
5 V which also can damage the module. If Jumper JP9 and JP16
remain open, no primary and secondary main power supply is
connected to the phyCORE-MPC5200B tiny. These jumper settings
should therefore not be used.
Summary of Contents for phyCORE-MPC5200B tiny
Page 30: ...phyCORE MPC5200B tiny 22 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 50: ...phyCORE MPC5200B tiny 42 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 92: ...phyCORE MPC5200B tiny 84 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 100: ...phyCORE MPC5200B tiny 92 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 102: ...phyCORE MPC5200B tiny 94 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 104: ...Published by PHYTEC Messtechnik GmbH 2006 Order No L 678e_1 Printed in Germany...