13.3
Functional Components on the phyCORE
Development Board HD200
This section describes the functional components of the phyCORE
Development Board HD200 supported by the
phyCORE-MPC5200B tiny and appropriate jumper settings to activate
these components. Depending on the specific configuration of the
phyCORE-MPC5200B tiny module, alternative jumper settings can be
used. These jumper settings are different from the factory default
settings as shown in
Figure 13
and enable alternative or additional
functions on the phyCORE Development Board HD200 depending on
user needs.
13.3.1
Power Supply at X1
Caution:
Only use the included power adapter to supply power to the
Development Board! Do not change modules or jumper settings while
the Development Board is supplied with power!
Permissible input voltage: +/-5 V DC regulated.
The required current load capacity of the power supply depends on the
specific configuration of the phyCORE-MPC5200B tiny mounted on
the Development Board as well as whether an optional expansion
board is connected to the Development Board. An adapter with a
minimum supply of 1.2 A is recommended.
Jumper Setting
Description
JP9
1 + 2
3.3 V primary main supply voltage
to the phyCORE-MPC5200B tiny
JP16
1 + 2
3.3 V as secondary main supply voltage
to the phyCORE-MPC5200B tiny
Table 14:
JP9, JP16 Configuration of the Main Supply Voltages VCC / VCC2
Summary of Contents for phyCORE-MPC5200B tiny
Page 30: ...phyCORE MPC5200B tiny 22 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 50: ...phyCORE MPC5200B tiny 42 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 92: ...phyCORE MPC5200B tiny 84 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 100: ...phyCORE MPC5200B tiny 92 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 102: ...phyCORE MPC5200B tiny 94 PHYTEC Messtechnik GmbH 2006 L 678e_0...
Page 104: ...Published by PHYTEC Messtechnik GmbH 2006 Order No L 678e_1 Printed in Germany...