The microcontroller firmware tries to automatically adjust to the baud
rate selected within the baud rate tab. However, it may occur that the
selected baud rate can not be attained. This results in a connection
error. In this case, try other baud rates to establish a connection.
Before attempting each connection, be sure to reset the target
hardware and render it into Flash programming mode (FPM) as
described in section 2.2.
Returning to the FlashTool98 tabsheet window, you will see tabs for
the following:
Bank Utilities
enable erasure and status check of whole banks of
memory specified by the user:
2
:
The number of banks shown on the Bank Utilities tabsheet varies depending on the size and
type of the Flash mounted on the phyCORE-ADuC812