5.10 Image Information and Status Information
Missed FrameCombine trigger counter
Counts missed triggers due to the FrameCombine
feature (see also Section 5.2.12). A missed FrameCombine trigger can occur if a trigger is
applied while filler rows are added to a frame due to a FrameCombine timeout.
5.10.2
Status Information
Status information is inserted in the 4 LSB in the last 3D data row (see bits labeled STAT in Fig.
5.13). LSB are transmitted first (see Table 5.10). The status information is divided in fields of 32
bits each, where every information field corresponds to one information parameter (see Table
5.11). Unused bits are set to 0.
Col 0
Col 1
Col 2
Col 3
...
Col n
STAT[3:0]
STAT[7:4]
STAT[11:8]
STAT[15:12]
...
STAT[4*n+3:4*n]
Table 5.10: STAT value
.
MAN052 12/2018 V3.2
79 of 131