6 Hardware Interface
6.6.6
I/O Wiring
The Photonfocus cameras include electrically isolated inputs and outputs. Take great care when
wiring trigger and strobe signals to the camera, specially over big distances (a few meters) and
in noisy environments. Improper wiring can introduce ground loops which lead to malfunction
of triggers and strobes.
There are two roads to avoid ground loops:
•
Separating I/O ground and power supply (ISO_GND and ISO_PWR) from camera power
(CAM_GND, CAM_PWR)
•
Using a common power supply for camera and I/O signals with star-wiring
Separate Grounds
To separate the signal and ground connections of the camera (CAM_GND, CAM_PWR, data
connections) from the I/O connections (ISO_GND, ISO_PWR, ISO_IN, ISO_OUT) is one way to
avoid ground loops. Fig. 6.14 shows a schematic of this setup. In this setup the power supplies
for the camera and for ISO power must be separate devices.
I
s o l a t o r
C A M _ G N D
I S O _ I N
I S O _ G N D
G r o u n d p l a n e v o l t a g e d i f f e r e n c e
I S O _ G N D
S e p a r a t e g r o u n d
n o g r o u n d l o o p
Figure 6.14: I/O wiring using separate ground
.
96 of 131
MAN052 12/2018 V3.2
Summary of Contents for MV1-D2048-3D03 Series
Page 10: ...1 Preface 10 of 131 MAN052 12 2018 V3 2...
Page 12: ...2 Introduction 12 of 131 MAN052 12 2018 V3 2...
Page 26: ...3 How to get started 3D GigE G2 26 of 131 MAN052 12 2018 V3 2...
Page 32: ...4 Product Specification 32 of 131 MAN052 12 2018 V3 2...
Page 71: ...5 4 Trigger and Strobe MAN052 12 2018 V3 2 71 of 131...
Page 84: ...5 Functionality 84 of 131 MAN052 12 2018 V3 2...
Page 120: ...11 Support and Repair 120 of 131 MAN052 12 2018 V3 2...
Page 122: ...12 References 122 of 131 MAN052 12 2018 V3 2...