5.4 Trigger and Strobe
MV1-D2048-3D03/04
MV1-D2048-3D03/04
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
1
µ
s
1.5
µ
s
t
d
−
RS422
−
input
65 ns
185 ns
t
jitter
0
21 ns
t
trigger
−
delay
0
0.34 s
t
burst
−
trigger
−
delay
0
0.34 s
t
burst
−
period
−
time
depends on camera settings
0.34 s
t
trigger
−
offset
(non burst mode)
170 ns
duration of 1 row
t
trigger
−
offset
(burst mode)
210 ns
210 ns
t
exposure
13
µ
s
0.34 s
t
strobe
−
delay
600 ns
0.34 s
t
strobe
−
offset
(non burst mode)
170 ns
170 ns
t
strobe
−
offset
(burst mode)
210 ns
210 ns
t
strobe
−
duration
200 ns
0.34 s
t
d
−
iso
−
output
150 ns
350 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 5.8: Summary of timing parameters relevant in the external trigger mode using camera MV1-D2048-
3D03/04
MAN052 12/2018 V3.2
65 of 131