5 Functionality
5.12.1
Ramp
Depending on the configured grey level resolution, the ramp test image outputs a constant
pattern with increasing grey level from the left to the right side (see Fig. 5.42).
Figure 5.42: Ramp test images: 8 bit output
5.12.2
LFSR
The LFSR (Linear Feedback Shift Register) test image outputs a constant pattern with a
pseudo-random grey level sequence containing every possible grey level that is repeated for
every row. The LFSR test pattern was chosen because it leads to a very high data toggling rate,
which stresses the interface electronic and the cable connection.
Figure 5.43: LFSR (linear feedback shift register) test image
In the histogram you can see that the number of pixels of all grey values are the same.
Please refer to application note [AN026] for the calculation and the values of the LFSR test
image.
82 of 131
MAN052 12/2018 V3.2
Summary of Contents for MV1-D2048-3D03 Series
Page 10: ...1 Preface 10 of 131 MAN052 12 2018 V3 2...
Page 12: ...2 Introduction 12 of 131 MAN052 12 2018 V3 2...
Page 26: ...3 How to get started 3D GigE G2 26 of 131 MAN052 12 2018 V3 2...
Page 32: ...4 Product Specification 32 of 131 MAN052 12 2018 V3 2...
Page 71: ...5 4 Trigger and Strobe MAN052 12 2018 V3 2 71 of 131...
Page 84: ...5 Functionality 84 of 131 MAN052 12 2018 V3 2...
Page 120: ...11 Support and Repair 120 of 131 MAN052 12 2018 V3 2...
Page 122: ...12 References 122 of 131 MAN052 12 2018 V3 2...