13 Hardware Interface
13.6.2
Single-ended Line Input
ISO_IN is a single-ended isolated input (see Fig. 13.2).
Fig. 13.3 shows a direct connection to the ISO_IN input.
I
S O _ I N
C a m
e r a
1
4 p o l . B i n d e r
C o n n e c t o r
I S O _ G N D
2
Y O U R _ G N D
Y O U R _ G N D
I S O _ G N D
C u r r e n t
L i m
i t e r
Figure 13.3: Direct connection to ISO_IN
Fig. 13.4 shows how to connect ISO_IN to TTL logic output device.
I
S O _ I N
C a m
e r a
1
4 p o l . B i n d e r
C o n n e c t o r
I S O _ G N D
2
Y O U R _ G N D
Y O U R _ G N D
&
Y O U R _ V C C
+
C o n t r o l L o g i c
I S O _ G N D
C u r r e n t
L i m
i t e r
Figure 13.4: Connection to ISO_IN from a TTL logic device
.
82 of 111
MAN078 12/2018 V1.1