5
Counter & Timer
5.1
Counter
C
o u n t e r
S
o
u
r
c
e
.
.
.
A c t i v a t i o n
R
i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
S
o
u
r
c
e
.
.
.
A c t i v a t i o n
R i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
S
o
u
r
c
e
.
.
.
A c t i v a t i o n
R i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
C o u n t e r
T r i g g e r
C o u n t e r
E v e n t
C o u n t e r
R e s e t
T i m e S t a m p
T i c k
C o u n t e r D u r a t i o n
C o u n t e r S t a r t V a l u e
C o u n t e r V a l u e
C o u n t e r S t a t u s
C o u n t e r R e s e t ( )
C o u n t e r V a l u e A t R e s e t
C o u n t e r A c t i v e
C o u n t e r S t a r t
C o u n t e r E n d
Figure 5.1: Counter Structure
Four general purpose counters are available (Counter0 . . . Counter3) which are used for
counting events. Each counter can be individually configured by software and controlled by
counter trigger, counter event and counter reset signals. This section describes the
configuration and the function of the counters.
Fig. 5.1 shows the structure of one counter. Along with the counter function itself it contains a
counter trigger source, a counter event source and a counter reset source selection and
activation block. Furthermore there is a counter active status signal, which is available in the
I/O control block (see Chapter 6). And the counter generates counter start and counter end
events, which can be used to trigger other blocks, like counter, timer, acquisition, frame or
exposure control.
5.1.1
Counter Usage
In a basic usage, at least a counter event source needs to be selected (see Section 5.1.5 for more
information about the counter event source selection). Once an event source has been
selected, the counter needs to be reset in order to start the counter. When started it counts
from a defined start value, which is configurable by the CounterStartValue property, and ends
counting events after a certain number of events, which is configurable by the
CounterDuration property.
MAN078 12/2018 V1.1
39 of 111
Summary of Contents for MV0 CMOSIS Series
Page 10: ...1 Preface 10 of 111 MAN078 12 2018 V1 1...
Page 38: ...4 Image Acquisition 38 of 111 MAN078 12 2018 V1 1...
Page 52: ...8 Image Format Control 52 of 111 MAN078 12 2018 V1 1...
Page 78: ...12 Precautions 78 of 111 MAN078 12 2018 V1 1...
Page 88: ...14 Mechanical Considerations 88 of 111 MAN078 12 2018 V1 1...
Page 90: ...15 Troubleshooting 90 of 111 MAN078 12 2018 V1 1...
Page 96: ...18 Support and Repair 96 of 111 MAN078 12 2018 V1 1...