
6.4 Encoder Reset Source
Encoder Idle
Encoder is idle, either no trigger sources are configured or the encoder is waiting
on the reset.
Encoder Up
The position counter last incremented.
Encoder Down
The position counter last decremented.
Encoder Static
The position counter hasn’t changed in the EncoderTimeout period. The
encoder also switches to this state when it is reset while in the idle state.
The EncoderTimeout is configurable by the user. If set to zero, no timeout is applied and the
encoder simply stays in the Up respectively Down state until the direction reverses. The
EncoderTimeout property only affects the encoder status.
6.4
Encoder Reset Source
The encoder reset source selects the signal which will be the used to reset the encoder. The
following signals sources are available:
Off
Disables the encoder reset.
Acquisition Trigger
Resets with the reception of the acquisition trigger.
Acquisition Start
Resets with the reception of the acquisition start event.
Acquisition End
Resets with the reception of the acquisition end event.
FrameTrigger
Resets with the reception of the frame trigger.
Frame Start
Resets with the reception of the frame start event.
Frame End
Resets with the reception of the frame end event.
Frame Burst Start
Resets with the reception of the frame burst start event.
Frame Burst End
Resets with the reception of the frame burst end event.
Exposure Start
Resets with the reception of the exposure start event.
Exposure End
Resets with the reception of the exposure end event.
User Output 0 ... 7
Resets the encoder as long as the selected user output bit is asserted. The
encoder remains in reset state until the selected user output bit is deasserted again (see
Section 4.7).
Counter 0 ... 3 Start
Resets with the reception the chosen counter start event.
Counter 0 ... 3 End
Resets with the reception the chosen counter end event.
Timer 0 ... 3 Start
Resets with the reception the chosen timer start event.
Timer 0 ... 3 End
Resets with the reception the chosen timer end event.
Software Signal Pulse 0 ... 7
Resets with the reception of chosen software signal pulse event
(see Section 4.7).
Line Input
Resets when the specified encoder trigger activation condition is met on the chosen
line.
Line input source has additionally a activation configuration, which needs to be set
accordingly. Following configuration values are available:
MAN082 09/2019 V1.0
51 of 125
Summary of Contents for MV0 3D06 Series
Page 10: ...1 Preface 10 of 125 MAN082 09 2019 V1 0...
Page 20: ...3 Product Specification 20 of 125 MAN082 09 2019 V1 0...
Page 38: ...4 Image Acquisition 38 of 125 MAN082 09 2019 V1 0...
Page 48: ...5 Counter Timer 48 of 125 MAN082 09 2019 V1 0...
Page 58: ...9 Image Format Control 58 of 125 MAN082 09 2019 V1 0...
Page 62: ...10 Frame Rate 62 of 125 MAN082 09 2019 V1 0...
Page 88: ...11 Image Data Processing 88 of 125 MAN082 09 2019 V1 0...
Page 92: ...12 Precautions 92 of 125 MAN082 09 2019 V1 0...
Page 100: ...13 Hardware Interface 100 of 125 MAN082 09 2019 V1 0...
Page 104: ...14 Mechanical Considerations 104 of 125 MAN082 09 2019 V1 0...
Page 106: ...15 Troubleshooting 106 of 125 MAN082 09 2019 V1 0...
Page 112: ...18 Support and Repair 112 of 125 MAN082 09 2019 V1 0...
Page 114: ...19 References 114 of 125 MAN082 09 2019 V1 0...