5 Counter & Timer
MissedFrameBurstStartTrigger
Count the number of missed frame burst start triggers. A
missed frame burst start trigger event is generated, when a frame burst start trigger
cannot be processed.
MissedExposureStartTrigger
Count the number of missed exposure start triggers. A missed
exposure start trigger event is generated, when an exposure start trigger cannot be
processed.
Missed Trigger
Counts the number of any generated missed triggers. The missed trigger is the
logical OR connection of MissedAcqStartTrigger, MissedFrameStartTrigger,
MissedFrameBurstStartTrigger and MissedExposureStartTrigger.
Time Stamp Tick
Counts the number of time stamp ticks. A time stamp tick generator is
available for every counter. It generates events with a rate, which can be configured. For
instances if the rate is set to 1 us and the counter event source is set to count time stamp
ticks, the counter increments every 1 us.
Line input source has additionally an activation configuration, which needs to be set
accordingly. Following configuration values are available:
Rising Edge
Counter counts rising edges on the selected line input.
Falling Edge
Counter counts falling edges on the selected line input
Both Edges
Counter counts both edges on the selected line input
Activation configuration has only effect when line input is selected as a counter
event source, otherwise this configuration is ignored.
The counter can be temporarely switched off, if the counter event source is set
to off. It continue counting events as soon as counter event source has been
selected again.
5.1.6
Counter Trigger Source
The counter trigger source selects the signal which will be used to start the counter. The
following signals sources are available:
Off
Disables the counter trigger.
Acquisition Trigger
Starts with the reception of the acquisition trigger event.
Acquisition Start
Starts with the reception of the acquisition start event.
Acquisition End
Starts with the reception of the acquisition end event.
FrameTrigger
Starts with the reception of the frame trigger event.
Frame Start
Starts with the reception of the frame start event.
Frame End
Starts with the reception of the frame end event.
Frame Burst Start
Starts with the reception of the frame burst start event.
Frame Burst End
Starts with the reception of the frame burst end event.
42 of 125
MAN082 09/2019 V1.0
Summary of Contents for MV0 3D06 Series
Page 10: ...1 Preface 10 of 125 MAN082 09 2019 V1 0...
Page 20: ...3 Product Specification 20 of 125 MAN082 09 2019 V1 0...
Page 38: ...4 Image Acquisition 38 of 125 MAN082 09 2019 V1 0...
Page 48: ...5 Counter Timer 48 of 125 MAN082 09 2019 V1 0...
Page 58: ...9 Image Format Control 58 of 125 MAN082 09 2019 V1 0...
Page 62: ...10 Frame Rate 62 of 125 MAN082 09 2019 V1 0...
Page 88: ...11 Image Data Processing 88 of 125 MAN082 09 2019 V1 0...
Page 92: ...12 Precautions 92 of 125 MAN082 09 2019 V1 0...
Page 100: ...13 Hardware Interface 100 of 125 MAN082 09 2019 V1 0...
Page 104: ...14 Mechanical Considerations 104 of 125 MAN082 09 2019 V1 0...
Page 106: ...15 Troubleshooting 106 of 125 MAN082 09 2019 V1 0...
Page 112: ...18 Support and Repair 112 of 125 MAN082 09 2019 V1 0...
Page 114: ...19 References 114 of 125 MAN082 09 2019 V1 0...