4 Image Acquisition
4.2.4
Acquisition End Trigger
The acquisition end trigger can be used to control the acquisition end procedure. The main
property of this trigger is the trigger mode. It can be set to on or off:
Acquisition End Trigger Mode = on
When the acquisition status is "Acquisition Active", it goes
to "Acquisition Trigger Wait" as soon as an acquisition end trigger has been received. The
camera stops capturing images and waits until an acquisition start trigger has been issued
again.
Acquisition End Trigger Mode = off
The acquisition end triggers are ignored and the
acquisition status remains active until an acquisition stop command has been executed or
the certain amount of frames has been captured, depending on the acquisition mode
parameter (see Section 4.2.1)
4.2.5
Acquisition Control Output Signals
The acquisition control block has the following output signals:
Acquisition Trigger Wait
An asserted acquisition trigger wait indicates, that the acquisition
control is waiting for an acquisition start trigger (see Section 4.2.3).
Acquisition Active
Acquisition active is a status signal, which is asserted, when the acquisition
has been started and deasserted, when the acquisition is stopped.
Acquisition Start
The acquisition start is an event, which is generated, when the acquisition is
started.
Acquisition End
The acquisition end is an event, which is generated, when the acquisition is
stopped.
Acquisition Trigger
The acquisition trigger is an event, which is generated, when the
acquisition is started by the acquisition start trigger (see Section 4.2.3).
Acquisition trigger wait and acquisition active status signal are routed to the I/O control block
and can there be selected for output on the physical output line or on one of the available leds
(see Chapter 7). Acquisition start, acquisition end and acquisition trigger event can be used to
trigger or to control other function in the camera, like counter or timer.
26 of 125
MAN082 09/2019 V1.0
Summary of Contents for MV0 3D06 Series
Page 10: ...1 Preface 10 of 125 MAN082 09 2019 V1 0...
Page 20: ...3 Product Specification 20 of 125 MAN082 09 2019 V1 0...
Page 38: ...4 Image Acquisition 38 of 125 MAN082 09 2019 V1 0...
Page 48: ...5 Counter Timer 48 of 125 MAN082 09 2019 V1 0...
Page 58: ...9 Image Format Control 58 of 125 MAN082 09 2019 V1 0...
Page 62: ...10 Frame Rate 62 of 125 MAN082 09 2019 V1 0...
Page 88: ...11 Image Data Processing 88 of 125 MAN082 09 2019 V1 0...
Page 92: ...12 Precautions 92 of 125 MAN082 09 2019 V1 0...
Page 100: ...13 Hardware Interface 100 of 125 MAN082 09 2019 V1 0...
Page 104: ...14 Mechanical Considerations 104 of 125 MAN082 09 2019 V1 0...
Page 106: ...15 Troubleshooting 106 of 125 MAN082 09 2019 V1 0...
Page 112: ...18 Support and Repair 112 of 125 MAN082 09 2019 V1 0...
Page 114: ...19 References 114 of 125 MAN082 09 2019 V1 0...