5.1 Counter
Exposure Start
Starts with the reception of the exposure start event.
Exposure End
Starts with the reception of the exposure end event.
User Output 0 ... 7
Starts and counts events as long as the selected user output bit is asserted.
When the counter is started, it ignores counter events as long as the corresponding user
output bit is deasserted (see Section 4.7).
Counter 0 ... 3 Start
Starts with the reception of the chosen counter start event.
Counter 0 ... 3 End
Starts with the reception of the chosen counter end event.
Timer 0 ... 3 Start
Starts with the reception of the chosen timer start event.
Timer 0 ... 3 End
Starts with the reception of the chosen timer end event.
Encoder
Starts with the reception of the encoder trigger event.
Action 0 ... 3
Starts with the receiption of the chosen action signal event.
Software Signal Pulse 0 ... 7
Starts with the reception of chosen software signal pulse event
(see Section 4.7).
Line Input
Starts when the specified counter trigger activation condition is met on the chosen
line.
Line input source has additionally an activation configuration, which needs to be set
accordingly. Following configuration values are available:
Rising Edge
Counter starts with the rising edge on the selected line input.
Falling Edge
Counter starts with the falling edge on the selected line input.
Both Edges
Counter starts with any edge on the selected line input.
Level High
Counter starts and is counting events as long as the level is high. When the counter
is started, it ignores counter events as long as the corresponding line input is low.
Level Low
Counter starts and is counting events as long as the level is low. When the counter
is started, it ignores counter events as long as the corresponding line input is high.
Activation configuration has only effect when line input is selected as a counter
trigger source, otherwise this configuration is ignored.
5.1.7
Counter Reset Source
The counter reset source selects the signal which will be the used to reset the counter. The
following signals sources are available:
Off
Disables the counter reset.
Counter Trigger
Resets with the reception of a trigger on the counter trigger source (see
Section 5.1.6).
Acquisition Trigger
Resets with the reception of the acquisition trigger.
Acquisition Start
Resets with the reception of the acquisition start event.
MAN082 09/2019 V1.0
43 of 125
Summary of Contents for MV0 3D06 Series
Page 10: ...1 Preface 10 of 125 MAN082 09 2019 V1 0...
Page 20: ...3 Product Specification 20 of 125 MAN082 09 2019 V1 0...
Page 38: ...4 Image Acquisition 38 of 125 MAN082 09 2019 V1 0...
Page 48: ...5 Counter Timer 48 of 125 MAN082 09 2019 V1 0...
Page 58: ...9 Image Format Control 58 of 125 MAN082 09 2019 V1 0...
Page 62: ...10 Frame Rate 62 of 125 MAN082 09 2019 V1 0...
Page 88: ...11 Image Data Processing 88 of 125 MAN082 09 2019 V1 0...
Page 92: ...12 Precautions 92 of 125 MAN082 09 2019 V1 0...
Page 100: ...13 Hardware Interface 100 of 125 MAN082 09 2019 V1 0...
Page 104: ...14 Mechanical Considerations 104 of 125 MAN082 09 2019 V1 0...
Page 106: ...15 Troubleshooting 106 of 125 MAN082 09 2019 V1 0...
Page 112: ...18 Support and Repair 112 of 125 MAN082 09 2019 V1 0...
Page 114: ...19 References 114 of 125 MAN082 09 2019 V1 0...