background image

1.  Read  these  instructions  before  operating  this 

apparatus.

2.  Keep these instructions for future reference.

3.  Heed all warnings to ensure safe operation.

4.  Follow all instructions provided in this document.

5.  Do not use this apparatus near water or in locations 

where condensation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install 

in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 

.

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 

with one wider than the other. A grounding type plug 

has two blades and a third grounding prong. The wide 

blade or the third prong is provided for your safety. If 

the provided plug does not   into your outlet, consult 

an electrician for replacement of the obsolete outlet.

10.  Protect  the  power  cord  from  being  walked  on  or 

pinched particularly at plug, convenience receptacles, 

and the point where they exit from the apparatus.

11.  Only  use  attachments/accessories 

  by  the 

manufacturer.

12.  Use  only  with  a  cart,  stand,  tripod,  bracket,  or 

table 

  by  the  manufacturer,  or  sold  with 

the  apparatus.  When  a  cart  is  used,  use  caution 

when  moving  the  cart/apparatus 

combination  to  avoid  injury  from  tip-

over.

13.  Unplug this apparatus during lighting 

storms  or  when  unused  for  long 

periods of time.

14.  Refer  all  servicing  to 

  service    personnel. 

Servicing is required when the apparatus has been 

damaged in any way, such as power-supply cord or 

plug  is  damaged,  liquid  has  been  spilled  or  objects 

have  fallen  into  the  apparatus,  the  apparatus  has 

been exposed to rain or moisture, does not operate 

normally, or has been dropped.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The  lightning  flash  with  arrowhead  symbol,  within  an 

equilateral  triangle,  is  intended  to  alert  the  user  to  the 

presence  of  uninsulated  “dangerous  voltage”  within  the 

product’

 

magnitude to constitute a risk of electric shock to persons.

The  exclamation  point  within  an  equilateral  triangle  is  in-

tended to alert the user to the presence of important operat-

ing and maintenance (servicing) instructions in the literature 

accompanying the appliance.

WARNING: 

To reduce the risk of 

 or electric shock, do 

not expose this apparatus to rain or moisture.

CAUTION: 

Use of controls or adjustments or performance 

of  procedures  other  than  those 

  may  result  in 

hazardous radiation exposure.

The apparatus shall not be exposed to dripping or splashing and that no objects 

 with liquids, such as vases, 

shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall 

remain readily operable. 

Warning

: the user shall not place this apparatus in the 

 area during the operation so that the mains switch 

can be easily accessible. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Summary of Contents for MU1722X

Page 1: ...User s Manual Manual del Usuario MU 1722X MU 1822X COMPACT MIXERS MIXERS COMPACTAS English Espa ol MU1822X...

Page 2: ...ONIC V2 0 08 19 2011 MU 1722X MU 1822X COMPACT MIXERS MIXERS COMPACTAS INTRODUCTION 4 INSTANT SETUP 4 MAKING CONNECTIONS 5 CONTROLS AND SETTINGS 6 SPECIFICATIONS 10 DIGITAL EFFECT TABLE 28 APPLICATION...

Page 3: ...hting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug...

Page 4: ...e degrees after the device is turned on 3 Plug all necessary instruments and equipment into the device s various inputs as required This may include line signal devices such as bass and drum machines...

Page 5: ...n their signal from theAUX and EFX controls located on each channel strip The MU1722X features 2 AUX sends whereas the MU1822X features a total of 3 5 AUX Returns These 1 4 TS inputs are for the retur...

Page 6: ...artists to listen to the music that is being playing Also included is a Pre Post button which alternates the feed to the AUX mixing bus between a post and pre fader feed 18 19 20 21 23 24 25 22 Rear...

Page 7: ...ttons These buttons located on each stereo input channel are used adjust the input sensitivity of the corresponding channel which will adapt the mixer to external devices which may use different opera...

Page 8: ...ual channel as is shown in the Channel Setup section of this manual The Solo button will illuminate when the Level Meter displays the audio properties of the Control Room Phones signal Master Section...

Page 9: ...the Main Left and Right and the Control Room Phones mixing buses respectively 50 Main L R Faders These two faders are the final level control for the Main Left and Right audio feeds sent to the Main L...

Page 10: ...ponse Mic input to any output 20Hz 60KHz 0 1 dB 0 1 dB 20Hz 100KHz 0 3 dB 0 3 dB Crosstalk 1KHz 0dBu 20Hz to 20KHz bandwidth channel in to main L R outputs Channel fader down other channels at unity 9...

Page 11: ...oct 75 Hz 18 dB oct Digital Effect Processor 16 effects with one main parameter control foot switch effect on off 16 effects with one main parameter control foot switch effect on off Power Requiremen...

Page 12: ......

Page 13: ...les una vez encendido el dispositivo 3 Enchufe todos los instrumentos y equipos necesarios en las varias entradas de dispositivo como sea necesario Estos podr an incluir dispositivos de se al de l nea...

Page 14: ...oles AUX y EFX localizados en cada tira de canal La MU1722X presenta 2 env os AUX en tanto la MU1822X presenta un total de 3 5 Retornos AUX Estas entradas de 1 4 TS son para retorno de audio a las mez...

Page 15: ...las entradas de Mic La Fuente Fantasma no causar da o a la mayor a de los micr fonos din micos sin embargo si no est seguro debe consultar el manual del usuario de micr fono 16 Interruptor de Energ a...

Page 16: ...t activado 30 Control de Nivel de Canal Fader Este control alterar el nivel de la se al que es enviada desde el canal correspondiente a bus de mezcla principal 31 Botones 4 10 Estos botones localizado...

Page 17: ...e mezcla EFX tomado desde los controles de nivel EFX en cada tira de canal cuyo audio es enviado a las salidas de Env o AUX 2 en MU1722X y Env o AUX 3 en MU1822X tambi n al procesador de efecto digita...

Page 18: ...l Izquierdo y Derecho y Control Room Phones respectivamente 50 Faders de Main L R Principal I D Estos dos faders son control de nivel final para alimentaciones de audio Principal Izquierdo y Derecho e...

Page 19: ...a de Mic a cualquier salida 20Hz 60KHz 0 1 dB 0 1 dB 20Hz 100KHz 0 3 dB 0 3 dB Crosstalk 1KHz 0dBu 20Hz a 20KHz ancho de banda entrada de canal a salidas main L R Fader de canal bajo otros canales en...

Page 20: ...de Efecto Digital 16 programas con un control de par metro principal e interruptor de pedal encendido apagado de efecto 16 programas con un control de par metro principal e interruptor de pedal encen...

Page 21: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN PHONIC CORPORATION...

Page 22: ...22 MU 1722X MU 1822X Phonic MU1722X MU1822X MU 1 AC 2 3 4 5 AC AC 6 1 ON LED Solo 2 3 0dB 4 Solo Main L R 5 0dB 6 7...

Page 23: ...722X 2 AUX MU1822X 3 5 1 4 TS MU1722X MU1822X AUX Return AUX Return 2 EFX Return AUX Return 1 2 1 4 Phone Mono AUX 2 Return 6 7 Control Room Phones 8 2T RCA MD 9 2T RCA Main L Main R Phones MU 10 1 4...

Page 24: ...LED EFX Return 35 LED 36 30 29 28 16 17 18 75Hz 75Hz 18dB oct 19 20 12KHz 15dB 21 15 dB 100Hz 8KHz MU1722X 3KHz 800Hz 3KHz 800Hz MU1822X 2 5KHz 22 80Hz 15dBu 23 AUX 1 AUX 24 AUX 3 AUX 25 PAN BAL BALA...

Page 25: ...d Master AUX AUX Send 1 Solo AUX Send Control Room Phones 42 AUX Send Master EFX AUX Send 2 MU1722X AUX Send 2 MU1822X Solo Control Room Phones 43 Control Room Phones Controls Control Room Phones 44 P...

Page 26: ...mm 11 12 48V DC 48V DC 20Hz 60KHz 0 1 dB 0 1 dB 20Hz 100KHz 0 3 dB 0 3 dB 1KHz 0dBu 20Hz to 20KHz Main L R 90 dB 90 dB 20Hz 20KHz Main Output 1 4 EQ Main Mix 1 3 2 4 6d Bu 86 5 dBu 86 5 dBu 84 dBu 84...

Page 27: ...z 100 8k Hz 800 Hz 800 Hz 3 kHz 3 kHz 12 kHz 12 kHz 75 Hz 18 dB oct 75 Hz 18 dB oct 16 16 90 260 VAC 50 60 Hz 90 260 VAC 50 60 Hz 4 2 kg 9 25 lbs 4 8 kg 10 6 lbs x x 11 8 x 4 1 x 13 4 300 x 104 5 x 34...

Page 28: ...Reverb Time 03 10 sec 6 Spring Reverb Time 03 10 sec 7 Opera Reverb Time 03 10 sec 8 Rev Vocal Reverb Time 03 10 sec 9 Slap Delay Delay Time 0 800 ms 10 Echo Delay Time 0 800 ms 11 Multi Pong Delay T...

Page 29: ...uir sin embargo pueden darle una idea de los posibles usos de las varias entradas y salidas que tiene La combinaci n correcta de micr fonos guitarras m quinas de tambor teclados dispositivos de grabac...

Page 30: ...MICROPHONES MICR FONOS GUITAR EFFECTS EFECTOS DE GUITARRA DRUM KIT KIT DE BATER A KEYBOARD TECLADO SIGNAL PROCESSOR PROCESADOR DE SE AL FOH SPEAKERS ALTAVOCES FOH AMPLIFIERS AMPLIFICADORES FOH ACTIVE...

Page 31: ...31 MU 1722X MU 1822X measurements are shown in mm inches MU1722X DIMENSIONS DIMENSIONES Todas las medidas est n mostradas en mm pulgadas mm inch...

Page 32: ...32 MU 1722X MU 1822X MU1822X measurements are shown in mm inches Todas las medidas est n mostradas en mm pulgadas mm inch...

Page 33: ...33 MU 1722X MU 1822X BLOCK DIAGRAMS DIAGRAMAES DE BLOQUE MU1722X...

Page 34: ...34 MU 1722X MU 1822X MU1822X...

Page 35: ...support Ah podr encontrar respuestas a las preguntas m s frecuen tes consejos t cnicos descarga de drivers instruc ciones de devoluci n de equipos y m s informaci n de mucho inter s Nosotros haremos t...

Page 36: ......

Reviews: