background image

ENVIRO 6S SLIDING GATE OPERATOR 

                                                                                       

4.

 

Mechanical Installation   

The ENVIRO 6S will handle gate weighting up to 300Kg and up to 8m if the proper installation procedures 
have been followed. 
The ENVIRO 6S gate operator operates by forcing a drive rack by a drive gear.    The entire configuration 
is shown in the diagram below. The gate operator must be installed on the inside of the gate. 

Sliding gate

Gate operator

Rack

Switch

Input power 

Wall

 

Fig.1 

Gate preparation 
Be sure the gate is properly installed and slides smoothly before installing the    ENVIRO 6S sliding gate 
operator. The gate must be plumb, level, and move freely. 
Conduit 
In order to protect the wires, use PVC conduit for low voltage power cable and control wires. Conduit 
must be preset into the concrete when it is poured. Wires within the conduit shall be located or protected 
so that no damage can result from contact with any rough or sharp part. 
Concrete pad 
The base unit of the gate operator requires a concrete pad in order to maintain proper stability.    The 
concrete pad should be approximately 400mm x 250mm x 200mm deep in order to provide for adequate 
weight and structure to insure proper stable installation. 
Anchors (see Fig.2) 
You can use anchor bolts, anchors, washers and nuts. These anchors must be set into the concrete 
when it is poured or you can use wedge anchors to fasten the operator. 

Summary of Contents for Enviro 6S

Page 1: ...Sliding Gate Operator User s Manual EN V I RO 6 S Ge a r Drive n http www phoenixgaragedoors com au...

Page 2: ...Important safety precautions 2 3 Main technical parameters 2 4 Mechanical Installation 3 5 Adjustment 5 6 Wire Connecting 6 7 Electrical and control board 7 8 Porgramming Process 8 9 Maintenance 10 1...

Page 3: ...operator has auto reverse function and the reverse power can change by user 2 Important safety information Carefully read and follow all safety precaution and warnings before attempting to install an...

Page 4: ...te must be plumb level and move freely Conduit In order to protect the wires use PVC conduit for low voltage power cable and control wires Conduit must be preset into the concrete when it is poured Wi...

Page 5: ...Nut Fig 2 Operator base see Fig 3 After the concrete has hardened mount the gate operator base to the concrete pad Verify that the base is properly leveled Using bolts and washers mount the gate oper...

Page 6: ...lly checking if the rack is resting on the gear and weld the second and third nut Bring another rack element near to the previous one Move the gate manually and weld the three nuts as the first rack t...

Page 7: ...rning the key counterclockwise and resume normal operation Fig 6 NOTE The gate operator needed reset limit after re tight the clutch by turning the key counterclockwise if the power failure and releas...

Page 8: ...ig 9 Motor black wire to T1 and red wire to T2 J1 transformer secondary AC24V 3 3A external Push Button J2 J3 J4 Single Button OSC and COM Three Button K G T and COM Photo beam PE and COM Output DC po...

Page 9: ...y 2 Press the transmitter button which you want to use button 1 2 3 4 then press the same button again 3 The dot on the LED display will flash then turn off 4 is indicated on the LED display then the...

Page 10: ...d the desired position You also can press OPEN to move the door open OPEN and CLOSE can be used to fine adjust the door position 5 Press the SET to confirm the close position 6 The door will do a comp...

Page 11: ...close until is indicated on the LED display release the close 11 will indicated on the LED display Press open H will indicated on the LED display Press SET to confirm Then Connect the photo beam follo...

Page 12: ...2 Make sure the infrared photocell function is disable Remote control does not work 1 Battery level may be low 2 Transmitter 1 Replace the battery inside the transmitter 2 Re program the transmitter...

Reviews: