ENVIRO 6S SLIDING GATE OPERATOR 

                                             

 
1. Products introduction 

please read the instructions carefully before proceeding. 
The operator contains Extra battery, transformer, control board and radio control.   
In case of power of failure, the operator is powered by a 24Vdc, 1.3Ah, extra battery. 
Intelligent charging system supplied. 
MCU is supplied to control the gate operator. 
Keypad / single button interface. 
Photo beam safety beam interface. 
User can select Auto-close feature   
Soft start & soft stop. 
Manual key release design for emergency purposes.

 

Gate operator has auto-reverse function, and the reverse power can change by user. 
 
 
2. Important safety information 

Carefully read and follow all safety precaution and warnings before attempting to  install and use this 

automatic gate operator. 

   

Make sure the Power supply(AC220V)  of operator is suitable for the power supply in  your area. 

 

 

3. Main technical parameters 

Unit Model 

ENVIRO 6S 

Power Supply 

220VAC

 

220V AC 
110V AC 

Maximum gate weight

 

300Kg

 

Maximum gate width

 

8m

 

Motor

 

24VDC 100W

 

Output torque

 

Max. 8N m

 

Work duty 

S

2

 30min 

Limit switch

 

Electronical Limit 

Gate Move speed

 

13m/min

 

Remote control range

 

30 meters

 

extra remote control 

20 

100 (2 included) 

Frequency 

433.92 MHz 

Noise 

60 dB 

Working temperature 

-20 C ~ +50 C 

Extra Battery 

24V 1.3 Ah 

 
 
 

Summary of Contents for Enviro 6S

Page 1: ...Sliding Gate Operator User s Manual EN V I RO 6 S Ge a r Drive n http www phoenixgaragedoors com au...

Page 2: ...Important safety precautions 2 3 Main technical parameters 2 4 Mechanical Installation 3 5 Adjustment 5 6 Wire Connecting 6 7 Electrical and control board 7 8 Porgramming Process 8 9 Maintenance 10 1...

Page 3: ...operator has auto reverse function and the reverse power can change by user 2 Important safety information Carefully read and follow all safety precaution and warnings before attempting to install an...

Page 4: ...te must be plumb level and move freely Conduit In order to protect the wires use PVC conduit for low voltage power cable and control wires Conduit must be preset into the concrete when it is poured Wi...

Page 5: ...Nut Fig 2 Operator base see Fig 3 After the concrete has hardened mount the gate operator base to the concrete pad Verify that the base is properly leveled Using bolts and washers mount the gate oper...

Page 6: ...lly checking if the rack is resting on the gear and weld the second and third nut Bring another rack element near to the previous one Move the gate manually and weld the three nuts as the first rack t...

Page 7: ...rning the key counterclockwise and resume normal operation Fig 6 NOTE The gate operator needed reset limit after re tight the clutch by turning the key counterclockwise if the power failure and releas...

Page 8: ...ig 9 Motor black wire to T1 and red wire to T2 J1 transformer secondary AC24V 3 3A external Push Button J2 J3 J4 Single Button OSC and COM Three Button K G T and COM Photo beam PE and COM Output DC po...

Page 9: ...y 2 Press the transmitter button which you want to use button 1 2 3 4 then press the same button again 3 The dot on the LED display will flash then turn off 4 is indicated on the LED display then the...

Page 10: ...d the desired position You also can press OPEN to move the door open OPEN and CLOSE can be used to fine adjust the door position 5 Press the SET to confirm the close position 6 The door will do a comp...

Page 11: ...close until is indicated on the LED display release the close 11 will indicated on the LED display Press open H will indicated on the LED display Press SET to confirm Then Connect the photo beam follo...

Page 12: ...2 Make sure the infrared photocell function is disable Remote control does not work 1 Battery level may be low 2 Transmitter 1 Replace the battery inside the transmitter 2 Re program the transmitter...

Reviews: