background image

ENVIRO 6S SLIDING GATE OPERATOR 

                                             

 

Manual operation   
In case of power failure use manual release key to open or close gate manually, use the release key as 
follow: 

  Fit the supplied key in the hole. 
  Turn the key 

clockwise

 to release the clutch. 

  Open and close the gate manually. 
  After power-restored use the manual release key to tight the clutch by turning the key 

counterclockwise

 and resume normal operation. 

 
 
 
 
 
 
 
 
 
 
 
 
                                        Fig.6 

NOTE The  gate  operator  needed  reset  limit  after  re-tight  the  clutch  by  turning  the  key 
counterclockwise if the power failure and released by hand.

 

 

6. Wire Connecting   

Connecting the battery   
Plug the terminal of Extra battery in the control board.   
NOTE:If you not use gate operator and power failure, please pull out the extra battery terminal.

 

 

Fig.7 

 

Release

Release key

Release hole

 

Battery

BLACK TO Charge BAT -

RED  TO Charge BAT +

Battery

RED  TO SOLAR BAT +

BLACK TO SOLAR BAT -

SOLAR PANEL

Summary of Contents for Enviro 6S

Page 1: ...Sliding Gate Operator User s Manual EN V I RO 6 S Ge a r Drive n http www phoenixgaragedoors com au...

Page 2: ...Important safety precautions 2 3 Main technical parameters 2 4 Mechanical Installation 3 5 Adjustment 5 6 Wire Connecting 6 7 Electrical and control board 7 8 Porgramming Process 8 9 Maintenance 10 1...

Page 3: ...operator has auto reverse function and the reverse power can change by user 2 Important safety information Carefully read and follow all safety precaution and warnings before attempting to install an...

Page 4: ...te must be plumb level and move freely Conduit In order to protect the wires use PVC conduit for low voltage power cable and control wires Conduit must be preset into the concrete when it is poured Wi...

Page 5: ...Nut Fig 2 Operator base see Fig 3 After the concrete has hardened mount the gate operator base to the concrete pad Verify that the base is properly leveled Using bolts and washers mount the gate oper...

Page 6: ...lly checking if the rack is resting on the gear and weld the second and third nut Bring another rack element near to the previous one Move the gate manually and weld the three nuts as the first rack t...

Page 7: ...rning the key counterclockwise and resume normal operation Fig 6 NOTE The gate operator needed reset limit after re tight the clutch by turning the key counterclockwise if the power failure and releas...

Page 8: ...ig 9 Motor black wire to T1 and red wire to T2 J1 transformer secondary AC24V 3 3A external Push Button J2 J3 J4 Single Button OSC and COM Three Button K G T and COM Photo beam PE and COM Output DC po...

Page 9: ...y 2 Press the transmitter button which you want to use button 1 2 3 4 then press the same button again 3 The dot on the LED display will flash then turn off 4 is indicated on the LED display then the...

Page 10: ...d the desired position You also can press OPEN to move the door open OPEN and CLOSE can be used to fine adjust the door position 5 Press the SET to confirm the close position 6 The door will do a comp...

Page 11: ...close until is indicated on the LED display release the close 11 will indicated on the LED display Press open H will indicated on the LED display Press SET to confirm Then Connect the photo beam follo...

Page 12: ...2 Make sure the infrared photocell function is disable Remote control does not work 1 Battery level may be low 2 Transmitter 1 Replace the battery inside the transmitter 2 Re program the transmitter...

Reviews: