ENVIRO 6S SLIDING GATE OPERATOR
9
Set open and close positions
1. Press and hold
SET
until number
1
is indicated on the LED display.
2. Press and hold
OPEN
to set open position(
now the door must be OPEN,, if not,please change the
motor wire red and black
), release the button until the door has reached the desired position. (You
also can press
CLOSE
to move the door close,
OPEN
and
CLOSE
can be used to fine adjust the
door position.)
3. Press the
SET
to confirm the open position, now number
2
is indicated on the LED display.
4. Press and hold
CLOSE
to set close position, release the button until the door has reached the
desired position. (You also can press
OPEN
to move the door open,
OPEN
and
CLOSE
can be used
to fine adjust the door position.)
5. Press the
SET
to confirm the close position.
6. The door will do a complete open and close cycle.
CLOSE
CODE
OPEN
SET
SET
OPEN
CODE
CLOSE
SET
OPEN
CODE
CLOSE
CLOSE
CODE
OPEN
SET
SET
OPEN
CODE
CLOSE
Fig.13
Automatic close (0~90 seconds adjustable)
1. Press and hold
OPEN
until is indicated on the LED display.
2. Press
OPEN
to increase the auto close time, press
CLOSE
to decrease time.
3. Set timer to
0
, the automatic close function will disable.
4. Press
SET
to confirm the setting.
5. Add 10 second per number
NOTE: Automatic close function is available only when the door is in fully opened position.
SET
CODE
CODE
SET
SET
CODE
OPEN
OPEN
OPEN
CLOSE
CLOSE
CLOSE
Setting obstruction force