background image

ENVIRO 6S SLIDING GATE OPERATOR 

                                             

Set open and close positions   

1.  Press and hold 

SET

 until number 

1

 is indicated on the LED display. 

2.  Press and hold 

OPEN

 to set open position(

now the door must be OPEN,, if not,please change the 

motor wire red and black

), release the button until the door has reached the desired position. (You 

also can press 

CLOSE 

to move the door close, 

OPEN

 and 

CLOSE

 can be used to fine adjust the 

door position.) 

3.  Press the 

SET

 to confirm the open position, now number 

2

 is indicated on the LED display. 

4.  Press  and  hold 

CLOSE 

to  set  close  position,  release  the  button  until  the  door  has  reached  the 

desired position. (You also can press 

OPEN 

to move the door open,

 OPEN

 and 

CLOSE

 can be used 

to fine adjust the door position.) 

5.  Press the 

SET

 to confirm the close position. 

6.  The door will do a complete open and close cycle.   

CLOSE

CODE

OPEN

SET

SET

OPEN

CODE

CLOSE

SET

OPEN

CODE

CLOSE

CLOSE

CODE

OPEN

SET

SET

OPEN

CODE

CLOSE

Fig.13 

 

Automatic close (0~90 seconds adjustable)

 

1. Press and hold 

OPEN

 until   is indicated on the LED display. 

2. Press

 OPEN

 to increase the auto close time, press 

CLOSE

 to decrease time. 

3. Set timer to 

0

, the automatic close function will disable. 

4. Press 

SET

 to confirm the setting. 

5. Add 10 second per number 

NOTE: Automatic close function is available only when the door is in fully opened position. 

SET

CODE

CODE

SET

SET

CODE

OPEN

OPEN

OPEN

CLOSE

CLOSE

CLOSE

 

 

Setting obstruction force 

Summary of Contents for Enviro 6S

Page 1: ...Sliding Gate Operator User s Manual EN V I RO 6 S Ge a r Drive n http www phoenixgaragedoors com au...

Page 2: ...Important safety precautions 2 3 Main technical parameters 2 4 Mechanical Installation 3 5 Adjustment 5 6 Wire Connecting 6 7 Electrical and control board 7 8 Porgramming Process 8 9 Maintenance 10 1...

Page 3: ...operator has auto reverse function and the reverse power can change by user 2 Important safety information Carefully read and follow all safety precaution and warnings before attempting to install an...

Page 4: ...te must be plumb level and move freely Conduit In order to protect the wires use PVC conduit for low voltage power cable and control wires Conduit must be preset into the concrete when it is poured Wi...

Page 5: ...Nut Fig 2 Operator base see Fig 3 After the concrete has hardened mount the gate operator base to the concrete pad Verify that the base is properly leveled Using bolts and washers mount the gate oper...

Page 6: ...lly checking if the rack is resting on the gear and weld the second and third nut Bring another rack element near to the previous one Move the gate manually and weld the three nuts as the first rack t...

Page 7: ...rning the key counterclockwise and resume normal operation Fig 6 NOTE The gate operator needed reset limit after re tight the clutch by turning the key counterclockwise if the power failure and releas...

Page 8: ...ig 9 Motor black wire to T1 and red wire to T2 J1 transformer secondary AC24V 3 3A external Push Button J2 J3 J4 Single Button OSC and COM Three Button K G T and COM Photo beam PE and COM Output DC po...

Page 9: ...y 2 Press the transmitter button which you want to use button 1 2 3 4 then press the same button again 3 The dot on the LED display will flash then turn off 4 is indicated on the LED display then the...

Page 10: ...d the desired position You also can press OPEN to move the door open OPEN and CLOSE can be used to fine adjust the door position 5 Press the SET to confirm the close position 6 The door will do a comp...

Page 11: ...close until is indicated on the LED display release the close 11 will indicated on the LED display Press open H will indicated on the LED display Press SET to confirm Then Connect the photo beam follo...

Page 12: ...2 Make sure the infrared photocell function is disable Remote control does not work 1 Battery level may be low 2 Transmitter 1 Replace the battery inside the transmitter 2 Re program the transmitter...

Reviews: