TP 6…PS
8/28
PHOENIX CONTACT
4109_en_B
Installation
1. Cut a hole in the enclosure according to the dimensions for the selected display.
Figure 3
-
1
Panel cutout dimensions
Refer to
for dimensions
Table 3
-
1
Overall and cutout dimensions with number of mounting clamps
Display size Overall dimensions
Cutout dimensions
1
1
Cutout dimensions are ±0.5 mm
Number of
mounting
clamps
A (mm)
B (mm)
X (mm)
Y (mm)
7 in.
202
146
195
139
8
10 in.
263
200
252
189
8
12.1 in.
302
229
292
219
10
15.6 in.
389
273
388
263
14
18.5 in.
465
310
455
300
14
21.5 in.
532
346
522
336
20
A
B
X
Y