38
by the charger. One array may have a damaged panel causing the voltage to be lower
than it should be.
Sample Solar Panel Data Sheet
Specification Sheet
Manufacturer
Typical PV panel (source: Internet)
Number of cells
120 cells
Maximum power rating (Pmax)
270.0 W
Warranted minimum Pmax
270.0 W
PV USA test condition rating (PTC)
241.3 Wp
Open circuit voltage (Voc)
38.4 V
Short circuit current (Isc)
9.18 A
Maximum power voltage (Vmp)
31.9 V
Maximum power current (Imp)
8.48 A
Module efficiency
16.3 %
Tolerance of maximum power rating
-0/+5 %
Static load test passed
5,400 Pa
Number of bus bars per cell
4
Normal operating cell temperature (NOCT)
46.5ºC
Maximum system voltage, DC
600 V & 1000 V (UL), 1000 V (IEC)
Fuse rating
15 A
Liability Exclusion
The manufacturer shall not be liable for damages, especially on the battery, caused by
use other than as intended or as mentioned in this manual or if the recommendations of
the battery manufacturer are neglected. The manufacturer shall not be liable if there has
been service or repair carried out by any unauthorized person, unusual use, wrong
installation, or bad system design.
Subject to change without notice. Version: 20180615
Made in Canada
Phocos AG - Germany
www.phocos.com
Summary of Contents for MPPTsolid
Page 2: ...2 Contents Bedienungsanleitung 3 21 User Manual 22 38 Manuel de l utilisateur 39 57 58 71...
Page 3: ...3 Ansichten Frontansicht R ckansicht...
Page 22: ...22 PanelView Front panelview Back panelview...
Page 33: ...33 Opening screen Opening screen with data logging enabled Help About...
Page 39: ...39 Diff rentes vues Vue panneau avant Vue panneau arri re...
Page 58: ...58...
Page 61: ...61 MPPTsolid MPPTsolid MPPTsolid MPPT MPPTsolid PowerWizard...
Page 68: ...68 edit OK Set MPPTsolid MPPTsolid Configuration Exit...