36
To change the logging frequency, select a rate from the control. Click the
Save and Exit
button to update the configuration and return to the main screen. The next session of
logging will be at this new sampling rate.
The data logging file is saved in the
Data
folder. The file is formatted in the CSV format
for easy import into Excel.
The data format in the CSV file is as follows:
Unit ID, Date, Time, Vin, Iin, Vout, Iout, Pin, Pout
MPPTsolid Charge Controller Specifications
A standard unit comes pre configured with the following default settings:
Electrical Input Specifications
Max solar input voltage
230 Voc
Input Range
30-230 Voc
Max. input current
100 A
Input protection
No internal fuse, 100 A in-line input circuit breaker
recommended
Electrical Output Specifications
Battery voltage range
24 – 72 V
Max. output current
100 A
Idle self-consumption
3 W max.
Power conversion efficiency
Up to 97%
Charge type
3-stage: float, main, boost
Battery type
Lead acid (GEL, AGM, flooded)
Output voltage range
User programmable 24-90 V via RS232 PC-interface
Battery temperature
User programmable (mV/K)
Status display
Green LED (operation), RS232 PC-interface
Output protection
No internal output fuse, 100 A in-line input circuit
breaker recommended
Data logging
Via RS232 PC-interface: PC data logging software
included
Operating temperature range
-25° to +55°C with derating > 40 °C
Mechanical Specifications
Dimensions (WxHxD)
208 x 89 x 434 mm
Summary of Contents for MPPTsolid
Page 2: ...2 Contents Bedienungsanleitung 3 21 User Manual 22 38 Manuel de l utilisateur 39 57 58 71...
Page 3: ...3 Ansichten Frontansicht R ckansicht...
Page 22: ...22 PanelView Front panelview Back panelview...
Page 33: ...33 Opening screen Opening screen with data logging enabled Help About...
Page 39: ...39 Diff rentes vues Vue panneau avant Vue panneau arri re...
Page 58: ...58...
Page 61: ...61 MPPTsolid MPPTsolid MPPTsolid MPPT MPPTsolid PowerWizard...
Page 68: ...68 edit OK Set MPPTsolid MPPTsolid Configuration Exit...