GRAN BARISTO 05 SERVICE MODE
23/30
HYDR
CIRCUIT
Boiler
Ev S
p/s 0
Pump
Ev D
^
^
25
Tank
DTray
50 Hz
Boliler
temperature (°C)
Mains voltage
supply frequency
Hydaulic Circuit
This page allow to test the functionality of hydraulic circuit:
Info:
mA:
indicates the maximum current (in mA) absorbed by the brew unit in motion. The value must
not exceed the following values:
- 600 mA with new the brew unit
- 450 mA with a brew unit with at least 5 product executed
- 130 mA without brew unit
Encoder Pulses Home-Work:
indicate the number of encoder pulses from Home to Work posi
-
tion or vice versa. Move the brew unit from Home to work or vice versa and the measured value
must bein the range [2000 – 2100].
H/W:
Becomes active when the Brew Unit reach HOME or WORK position
Pres:
Becomes active if the Brew Unit is present in machine
DDr:
Becomes active if the Dreg Drawer is present in machine
Door:
Becomes active if the Frontal Door is closed
The meaning of the sectors are the following:
Command:
Boiler:
when pressed activate/deactivate the boiler if the temperature is less than 90°C
Pump:
when pressed activate/deactivate the pump
Ev S:
when pressed activate/deactivate the Steam/Water electrovalve (24V Dc)
Ev D:
when pressed activate/deactivate the discharge electrovalve (24V Dc)
Info:
p/s:
indicate the current number of water flow expressed in pulses/sec. When is activated the
pump and one electrovalve the value measured must be equal to or greater than 10 p/s.
Tank:
Becomes active when the water into tank reach sensor level
DripTray:
Becomes active when the water into drip tray reach sensor level
Frequency:
indicate the frequency of mains voltage supply
Boiler Temperature:
indicate the boiler temperature in °C
Press
UP
( ): go to next page
Press
UP
( ): go to next page
Summary of Contents for Saeco GranBaristo
Page 3: ...GRAN BARISTO CHAPTER 1 INTRODUCTION ...
Page 9: ...GRAN BARISTO CHAPTER 2 TECHNICAL SPECIFICATIONS ...
Page 17: ...GRAN BARISTO CHAPTER 3 BRIEF INSTRUCTIONS ...
Page 24: ...GRAN BARISTO CHAPTER 4 OPERATING LOGIC ...
Page 32: ...GRAN BARISTO CHAPTER 5 SERVICE MODE ...
Page 63: ...GRAN BARISTO CHAPTER 6 RERVICING AND MAINTENANCE ...
Page 66: ...GRAN BARISTO CHAPTER 7 DISASSEMBLY ...
Page 77: ...GRAN BARISTO CHAPTER 8 NOTES ...
Page 78: ...GRAN BARISTO 08 NOTES 1 1 ...
Page 79: ...GRAN BARISTO CHAPTER 9 WATER CIRCUIT DIAGRAM ...
Page 81: ...GRAN BARISTO CHAPTER 10 ELECTRICAL DIAGRAM ...
Page 82: ...GRAN BARISTO 10 ELECTRICAL DIAGRAM 1 2 Gran Baristo Avanti ...
Page 83: ...GRAN BARISTO 10 ELECTRICAL DIAGRAM 2 2 Gran Baristo ...