GRAN BARISTO 04 OPERATING LOGIC
4/7
An NTC is used as a temperature sensor; in the event of overheating this reduces boiler element
power consumption.
The electronic system detects the current boiler temperature from the drop in voltage of the
sensor and adjusts it accordingly.
Heating element values and corresponding temperatures: see table.
4.4. Temperature sensor (adjustment)
Temp. (°C)
R nom (kΩ)
ΔR (+/- %)
20
61.465
8.6
50
17.599
5.9
75
7.214
4.1
80
6.121
3.7
85
5.213
3.4
90
4.459
3.1
100
3.3
2.5
125
1.653
3.9
150
0.893
5.1
4.3. Single microswitch
The gear motor is powered by a direct
current motor that engages with the
smaller double toothed wheel using a
worm screw. The unit is mounted on the
axle of the large gear wheel and when
a coffee is requested, it moves from the
standby position to the dispensing posi
-
tion, and then back to the standby posi
-
tion again.
- Standby position: 1
- Dispensing position: 2
2
1
Summary of Contents for Saeco GranBaristo
Page 3: ...GRAN BARISTO CHAPTER 1 INTRODUCTION ...
Page 9: ...GRAN BARISTO CHAPTER 2 TECHNICAL SPECIFICATIONS ...
Page 17: ...GRAN BARISTO CHAPTER 3 BRIEF INSTRUCTIONS ...
Page 24: ...GRAN BARISTO CHAPTER 4 OPERATING LOGIC ...
Page 32: ...GRAN BARISTO CHAPTER 5 SERVICE MODE ...
Page 63: ...GRAN BARISTO CHAPTER 6 RERVICING AND MAINTENANCE ...
Page 66: ...GRAN BARISTO CHAPTER 7 DISASSEMBLY ...
Page 77: ...GRAN BARISTO CHAPTER 8 NOTES ...
Page 78: ...GRAN BARISTO 08 NOTES 1 1 ...
Page 79: ...GRAN BARISTO CHAPTER 9 WATER CIRCUIT DIAGRAM ...
Page 81: ...GRAN BARISTO CHAPTER 10 ELECTRICAL DIAGRAM ...
Page 82: ...GRAN BARISTO 10 ELECTRICAL DIAGRAM 1 2 Gran Baristo Avanti ...
Page 83: ...GRAN BARISTO 10 ELECTRICAL DIAGRAM 2 2 Gran Baristo ...