GRAN BARISTO 05 SERVICE MODE
24/30
Grinder
Display
This page allow to test the functionality of grinder:
This page allow to change display settings (brightness and contrast):
The meaning of the sectors are the following:
Command:
A1:
Selected Coffee Strength. If pressed change the current coffee strength from A1 to A6
A1:
Very Mild
A2:
Mild
A3:
Regular
A4:
Strong
A5:
Very Strong
A6:
Extra Strong
A/AA:
A = use the current coffee strength ; AA = add 33% of time to the current coffee strength
GTest:
Activate/Deactivate the grinder for a time corresponding to the selected coffee strength.
Info:
Time during grinding:
indicate the time while the machine is grinding in msec
DDOOR:
indicate the status of hopper door (colored box -> closed)
Z-cr:
Colored box indicate that the measure of zero crossing is FAIL.
The meaning of the sectors are the following:
Command:
C+:
increase the display contrast
C- :
decrease the display contrast
L+:
increase the display brightness
L- :
decrease the display brightness
GRINDER
^
GTest
A1
0
A/AA
^
^
^
3500
DDoor
^
Z-Cr
Grinder Time for
selected coffee
strength
Time during grinding
Zero crossing
FAIL
DISLAY
^
C +
C -
^
L+
L -
^
^
100
100
^
^
Brightness (%)
Contrast (%)
Press
UP
( ): go to next page
Summary of Contents for Saeco GranBaristo
Page 3: ...GRAN BARISTO CHAPTER 1 INTRODUCTION ...
Page 9: ...GRAN BARISTO CHAPTER 2 TECHNICAL SPECIFICATIONS ...
Page 17: ...GRAN BARISTO CHAPTER 3 BRIEF INSTRUCTIONS ...
Page 24: ...GRAN BARISTO CHAPTER 4 OPERATING LOGIC ...
Page 32: ...GRAN BARISTO CHAPTER 5 SERVICE MODE ...
Page 63: ...GRAN BARISTO CHAPTER 6 RERVICING AND MAINTENANCE ...
Page 66: ...GRAN BARISTO CHAPTER 7 DISASSEMBLY ...
Page 77: ...GRAN BARISTO CHAPTER 8 NOTES ...
Page 78: ...GRAN BARISTO 08 NOTES 1 1 ...
Page 79: ...GRAN BARISTO CHAPTER 9 WATER CIRCUIT DIAGRAM ...
Page 81: ...GRAN BARISTO CHAPTER 10 ELECTRICAL DIAGRAM ...
Page 82: ...GRAN BARISTO 10 ELECTRICAL DIAGRAM 1 2 Gran Baristo Avanti ...
Page 83: ...GRAN BARISTO 10 ELECTRICAL DIAGRAM 2 2 Gran Baristo ...